INSTRUCTIONS - ELECTRICINEMA
Type A, B & C. Connect IP Projection Screen including IP Protocol
CONNECT IP MODULES 1 & 2
All inputs on module 1 are accessed by removing right hand end cap of screen canister
1. CONTACT CLOSE INPUT
Contact Close Input for local control
Requires 2 x Momentary contacts duration minimum 50 milliseconds
All inputs on module 1 are accessed by removing right hand end cap of screen canister
Dedicated contact for Up & Down
Stop command is close opposite travel contact or both Up & Down together
1. Contact Close Input
2. DC TRIGGER INPUT
Down command is sent when a DC Voltage of 3 Volts @ 1mA minimum is applied to input, a
Up command is sent
Up command is sent when a DC Voltage of less than 1.0 Volts DC @ 1mA is applied to input,
a Down command is sent
Maximum cable length 75 meters approximately based 24 AWG gauge cable