Instructions for Operation and Care of BestCare Ligature-Resistant Faucets

Pneumatic Valve Connections

1/4"
Min.
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
PNEUMATIC TUBING LINE KEY
Ferrule
Nut
Leave a minimum 1/4" of polyethylene
tubing through the Ferrule Nut on the
pushbutton assembly. This is necessary
to ensure proper tubing connection. Do
not over tighten Ferrule Nuts
1/8" O.D. Air Tube
1/4" O.D. Air Tube
Turn timing screw clockwise to
increase timing.
Timing Screw to adjust
Ferrule
timing, turn timing screw
Nut
9