Instructions for Operation and Care of BestCare Ligature-Resistant Faucets
-SO Sensor/ -PPZ Programmable Piezo Pushbutton Connections
WH3377-PPZ
-SO SENSOR
-PPZ PUSHBUTTON
RED
TRANSFORMER
RED
BLUE
SOLENOID VALVE
-SO Sensor Operation
Range Adjustment
1. Make sure power supply is
disconnected from sensor and make
short circuit on red wires.
See DETAIL A.
2. Connect power supply to sensor. Red
light should be flashing.
3. Move hand in front of sensor to
distance of 2" to 4" within 5 seconds
and wait until red light flashes quickly.
4. Move hand to desired sensing distance.
See DETAIL B.
5. Hold hand at desired sensing distance
until red light stops flashing and
solenoid activates.
See DETAIL C.
10
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
BLUE
Transformer must be
plugged into a GFI
protected circuit.
Fixture must be earth
grounded per N.E.C.
or applicable codes.
WH3376-PPZ/-SO
Jumper
DETAIL A
By Others
DETAIL B
DETAIL C