Valve To Deck Installation - Whitehall BestCare WH3376-WSF Installation, Operation And Maintenance Manual

Ligature resistant faucets
Table of Contents

Advertisement

Instructions for Operation and Care of BestCare Ligature-Resistant Faucets
BestCare Faucet WH3376-WSF & WH3377-WSF
A- Prior to installing, remove Diaphragm
Retainer 1 , Hex Nut 2 , Washer 3 ,
and Spacer 4 from the Pushbutton
Assembly.
B- Fix the Pushbutton Assemblies to the
Basin thru hole and fasten using the
Spacer 4 , Washer 3 , Hex Nut 2
and Diaphragm Retainer 1 .
C- Remove the 1/4" OD x 1/4" NPT Push-
In Fitting 5 , Locknut 6 and Washer
7 from the Conical Faucet 8 .
D- Mount the Faucet 8 to the Basin.
Install Washer 7 and Nut 6 to Faucet
8 from the Deck underside to secure.
Assemble 1/4" NPT Push-In Fitting 5
to the Faucet Adapter 9 .
BestCare Faucet WH3376-WSF-SO & WH3376-WSF-SO-BAT
8
3
2
1
6
5
4
4
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
7
1 1 4 " Max
9
4
3
2
1
7
6
5
A- Prior to installing, remove Hex Nut 1 ,
Washer 2 and Spacer 3 from the
Sensor Assembly Sleeve.
B- Fix the Sensor Assembly to the Basin
by passing Wires thru the hole and
fasten using the Hex Nut 1 , Washer
2 and Spacer 3 .
C- Remove the 1/4" OD x 1/4" NPT Push-
In Fitting 4 , Locknut 5 and Washer
6 from the Conical Faucet 7 .
D- Mount the Faucet 7 to the Basin.
Install Washer 6 and Nut 5 to Faucet
7 from the Deck underside to secure.
Assemble 1/4" NPT Push-In Fitting 4
to the Faucet Adapter 8 .
8