Whitehall BestCare WH3376-WSF Installation, Operation And Maintenance Manual page 5

Ligature resistant faucets
Table of Contents

Advertisement

Instructions for Operation and Care of BestCare Ligature-Resistant Faucets
BestCare Faucet WH3376-WSF-PPZ/-BAT & WH3377-WSF-PPZ/-BAT
A- Prior to installing, remove Hex Nut 1 ,
Washer 2 and Spacer 3 from the
Piezo Button Sleeve.
B- Fix the Piezo Button Assemblies to the
Basin by passing Wires thru hole and
fasten using the Hex Nut 1 , Washer
2 and Spacer 3 .
C- Remove the 1/4" OD x 1/4" NPT Push-
In Fitting 4 , Locknut 5 and Washer
6 from the Conical Faucet 7 .
D- Mount the Faucet 7 to the Basin.
Install Washer 6 and Nut 5 to Faucet
7 from the Deck underside to secure.
Assemble 1/4" NPT Push-In Fitting 4
to the Faucet Adapter 8 .
BestCare Faucet WH3375-SO/-BAT
1
5
7
3
3
WHITEHALL MANUFACTURING • P .O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
2
1
1 1 4 " Max
4
6
8
3
2
1
6
5
4
A- Install the Threaded Rod 1 from the
Hardware Package to the Faucet
Assembly 2 .
B- Apply Teflon Tape to the 1/4" NPT
Titting 3 then install into the Faucet
Assembly.
C- Feed the Faucet Assembly Wires
through the center hole and mount
Faucet Assembly 2 and Gasket on
the Basin and fasten using the
provided Step Washer 4 , Flat
Washer 5 , Lock Washer 6 and Hex
Nut 7 .
Note:
1. Provide 3-hole, 4" Centerset Deck
openings with ø1" minimum to ø1-1/2"
maximum holes for Faucet installation.
7
1" Max
5

Advertisement

Table of Contents
loading

Table of Contents