Riello - Slant/Fin EUTECTIC EC-10DV Series Installation And Operating Instructions Manual

Direct vent oil-fired water boiler/no. 2 oil
Hide thumbs Also See for EUTECTIC EC-10DV Series:
Table of Contents

Advertisement

12

Riello

Burner
Model
Boiler Model
EC-13DV
BF-3
EC-14DV
BF-3
EC-15DV
BF-5
EC-16DV
BF-5
Models BF-3 & BF-5 Electrode Setting
Figure 4.
Turbulator location
Picture 1.
TURBULATOR SETTING
1. Loosen nut, 1, then turn the screw, 2, until the index marker, 3, is aligned with the correct index number.
2. Retighten the retaining nut, 1.
The numbers on the casting are there to denote the high and low end of the scale – For Model BF-5, zero and four are
scale indicators only. From left to right, the first line is 4 and the last line is 0.
The air/oil ratio depends on accurate setting of the turbulator disc and air damper.
Be careful when making this adjustment as an incorrect setting will result in an unsatisfactory operation.
See figure 5 & 6.
RIELLO BURNER DATA
Firing
Blast
Rate
Size
Tube
GPH
(GPH)
Long
0.65
0.55
Long
0.8
0.7
Short
1
0.75
Short
1.15
0.85
3
2
1
Nozzles
Angle &
Oil Pump
Type
Mfg.
(PSIG)
80*A
Delavan
133
80*B
Delavan
130
60*A
Delavan
178
60*W
Delavan
182
EUTECTIC EC-10 DV
Approx.
Boiler
Approx.
Head
Flue
Air
Setting
Baffle
Setting
0
4.5
2
3
5.5
none
1
4.4
none
2
4.2
none
Burner
Insertion
Depth
7"
7"
4-1/4"
4-1/4"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents