EUTECTIC EC-10 DV
Riello
Boiler
Burner
Blast
Model
Model
Tube
EC-13DV
BF-3
Long
EC-14DV
BF-3
Long
EC-15DV
BF-5
Short 3.78
EC-16DV
BF-5
Short 4.35 1.15 3.21 0.85 60*W Delavan 1255
Models BF-3 & BF-5 Electrode Setting
Figure 4.
TURBULATOR SETTING
1. Loosen nut, 1, then turn the screw, 2, until the index marker, 3, is aligned with the correct index number.
2. Retighten the retaining nut, 1.
The numbers on the casting are there to denote the high and low end of the scale – For Model BF-5, zero and four are
scale indicators only. From left to right, the first line is 4 and the last line is 0.
The air/oil ratio depends on accurate setting of the turbulator disc and air damper.
Be careful when making this adjustment as an incorrect setting will result in an unsatisfactory operation.
See figure 5 & 6.
RIELLO BURNER DATA
Firing Rate
Nozzles
GPH
GPH
L/hr
L/hr
2.46 0.65 2.08 0.55 80*A Delavan
3.02
0.8
2.65 0.7
1
2.84 0.75 60*A Delavan 1227
Oil Pump
Angle
&
Type
Mfg.
(PSIG)
kPa
917
80*B Delavan
896
Turbulator location
Picture 1.
Approx.
Approx.
Boiler
Head
Air
Flue
Setting
Setting
Baffle
133
0
4.5
130
3
5.5
none 177.8 7.00
178
1
4.4
none 107.95 4.25
182
2
4.2
none 107.95 4.25
10
Burner
Insertion
Depth
mm
in.
2
177.8 7.00
3
2
1
Need help?
Do you have a question about the EUTECTICEC-15DV and is the answer not in the manual?
Questions and answers