Symbol SE955 Integration Manual page 234

Table of Contents

Advertisement

B-4
SE955 Integration Guide
Code Type
Option Value
Trioptic Code 39
Example: A trioptic bar code 412356 is transmitted as ]X0412356
Code 128
Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as ]C1AimId
I 2 of 5
Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123
Codabar
Example: A Codabar bar code without check digit, 4123, is transmitted as ]F04123
Code 93
Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905
MSI
Example: An MSI bar code 4123, with a single check digit checked, is transmitted as ]M04123
D 2 of 5
Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123
Table B-3. Modifier Characters (Continued)
0
No option specified at this time. Always transmit 0.
0
Standard data packet, No Function code 1 in first symbol position.
1
Function code 1 in first symbol character position.
2
Function code 1 in second symbol character position.
0
No check digit processing.
1
Reader has validated check digit.
3
Reader has validated and stripped check digit.
0
No check digit processing.
1
Reader has checked check digit.
0
No options specified at this time. Always transmit 0.
0
Mod 10 check digit checked and transmitted.
1
Mod 10 check digit checked but not transmitted.
0
No options specified at this time. Always transmit 0.