8-48
SE955 Integration Guide
Transmit I 2 of 5 Check Digit
Parameter # 0x2C
Scan this symbol to transmit the check digit with the data.
Scan this symbol to transmit data without the check digit.
Convert I 2 of 5 to EAN-13
Parameter # 0x52
This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. To accomplish this, I 2 of 5
must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
Transmit I 2 of 5 Check Digit (Enable)
(0x01)
*Do Not Transmit I 2 of 5 Check Digit (Disable)
(0x00)
Convert I 2 of 5 to EAN-13 (Enable)
(0x01)
*Do Not Convert I 2 of 5 to EAN-13 (Disable)
(0x00)