iring diagram
Fig. D-4
Connect Flag receptacles to Brush holders so that their wire connected portions and the lead wires
come to the bottom of Handle side. Their wire connected portions and the lead wires must not face
Handle cover side.
Guide Field lead wire (white)
on Rib C side of Pin.
Put connecting lead wires
(white), (purple) between
rib B and rib C.
Rib C
Rib B
Switch
Put Connecting lead wires
(white), (orange) to lead
wire holder of Switch.
And tighten them between
lead wire holder and the
switch's terminal to which
they are connected.
Noise suppressor
Insulated receptacle
Wiring in Handle section
Handle side
Handle
cover side
Put connecting lead wire (purple) to lead
wire holder, and tighten it between lead
wire holder and terminal of Switch.
And put Field lead wire (white) between
Rib D and inner wall of Switch trigger side.
Choke coil
Choke coil
Put the following lead wires to this lead wire holder.
* Connecting lead wire (orange)
* Field lead wire (black)
* Grounding lead wire (clear) of
Noise suppressor
Handle side
Handle
cover side
Put Field lead wire (white)
between Boss and inner wall.
Boss
Rib D
Pin
P 25/ 25
Boss
Pass Field lead wire (black)
and Grounding lead wire
(clear) of Noise suppressor
between Boss and inner wall
of switch side.
To any of these lead wire holders,
put the following lead wires.
* Connecting lead wire (orange)
* Field lead wire (black)
* Grounding lead wire (clear) of
Noise suppressor

Advertisement