Download Print this page

Installation Instructions - Santec Designer Series Instruction Booklet

1/2" thermostatic trim with volume control / 2/3-way diverter

Advertisement

INSTALLATION INSTRUCTIONS

General characteristic
- Santec thermostatic valve is suitable for most water heater systems
provided it is installed correctly
- Low pressure storage heaters are not recommended for this application
Cartridge ge Cleaning
Cleaning
After years of use, impurities and lime scale
can restrict the water flow. To clean the
cartridge, please follow these instructions:
1- Remove the handle screw, handle trim,
trim plate screws, and
trim
2- Shut off the water line by turning the
check valve shut off mechanism clockwise.
Make sure that the both hot and cold sides
are closed.
3- Remove the
cartridge using a 30mm
4- Wash the
filter under running water or soak it with vinegar or a descaling agent.
5- Reassemble
the cartridge making sure that the blue lines on the cartridge are aligned.
6- Open the
check valve shut-off mechanism, turn on the water, and check water flow.
7- If the water
flow is normal, reassemble the trims. .
IF THE ACTUAL WATER TEMPERATURE IS DIFFERENT FROM THE DIAL :
1- Remove the thermostatic handle with the provided Allen key
2- Turn the water on through the volume control and measure the
actual water temperature with a regular thermometer.
3- Turn the dial until the thermometer shows 100F.
4- Remove the dial handle from the valve.
5- Align the 100F with the center mark
of the valve cylinder, replace screw and tighten.
6- Insert the handle into the cartridge
7- Tighten the handle screw with provided Allen key.
plate.
wrench.
WARMER
WARMER
WARM
HOT
HOT
COLD
WARM
COLD
0 4

Advertisement

loading

This manual is also suitable for:

Ph9707Ph9710Ph9708Ph9711