UniData Communication Systems Starflow QSD Manual page 11

Table of Contents

Advertisement

4.1.2 Channels Table
These Channels are data registers within the instrument. That the SDI-12 parameters are assigned to
the Channels and their order of return can be configured using the Sonic software utility and SDI-12
eXtended command.
Channel
Description
0
Water Temperature
1
Battery Voltage
2
Ultrasonic Depth
3
CW Water Velocity
4
RSSI (signal level)
5
Signal Spread
10
X-Axis Tilt
11
Y-Axis Tilt
12
Pressure Depth
13
Barometric Reference
70
Conductivity (UC)
72
Conductivity (TC)
Default SDI-12 Parameters and Channels assignment are listed below
Parameter Channel
1
0
2
1
3
2
4
3
5
4
6
5
7
72
8
12
9
13
10
unassigned
11
unassigned
12
unassigned
13
unassigned
14
unassigned
15
unassigned
16
unassigned
Unidata Manual - 6527B and 6537A Starflow QSD User Manual 17 01 2020.docx
Manual – Starflow QSD Model 6527B and 6537A
Description
Water Temperature
Battery Voltage
Ultrasonic Depth
CW Water Velocity
RSSI (signal level)
Signal Spread
Conductivity (TC)
Pressure Depth
Barometric Reference
Units
Example
1/10 ºC
+152
1/100 Volts
+1302
mm
+123
+/- mm/s
-234
no units
+66
no units
+45
+/- deg
-9
+/- deg
7
+/- mm
+123
+ mm
+10120
µS/cm
+2350
µS/cm
+2350
Units
1/10 ºC
1/100 Volts
mm
+/- mm/s
no units
no units
µS/cm
+/- mm
+ mm
Meaning
15.2ºC
13.02Volts
123mm
234mm/s -ve flow
66 (no units)
45 (no units)
9 deg left tilt
7 deg forward tilt
123mm
10120mm
2350µS/cm
2350µS/cm
Page 9