1. GENERAL INFORMATION

1.1 Product Identification

Identification of your product can be found on the
label attached to the product. The label contains
information about the product according to EN
12897: 2016 and EN 60335-2-21, in addition to
other useful data. See Declaration of Conformity
at www.osohotwater.com for more information
OSO products are designed and manufactured
according to:
Tank standard
Safety standard
Welding standard
OSO Hotwater AS is certified according to
Quality
Environment
Working Environment OHSAS 18001

1.2 CE marking

The CE mark shows that the product complies
with the relevant Directives. See Declaration of
Conformity at www.osohotwater.co.uk for more
information.
The product complies with he directives for:
• Low voltage
• Electromagnetic compatibility EMC 2014/30/EU
• Press Equipment
1.3 ErP data - Technical Data Sheet
TDS - Technical Data Sheet - Direct electric water heater - ErP data
Directive: 2010/30/EU Regulation: EU 812/2013
Standing heat loss according to standard: EN 12897: 2016
Trade mark
OSO Hotwater AS
The indirect hot water storage tank (Slimline RI) is intended to be connected to a high efficiency external energy
source. The immersion heaters are intended for backup and supplementary use only. Immersion heaters as sole
heat source should be avoided and would lead to higher energy consumption and higher operating cost.
4
EN 12897:2016
EN 60335-2-21
ISO 3834-2
ISO 9001
ISO 14001
LVD 2014/35/EU
PED 2014/68/EU
M T.
item no.
1326200 RI 150 - 2+2 kW / 1x230V - 2+2 kW / 1x240V
1.4 General information
Thank-you for purchasing the OSO Slimline RI /
RD indirect / direct hot water cylinder.
OSO advise that the connecting pipes and
electrical cables are fixed in place prior to the
positioning of the cylinder. Moving the cylinder
into position should be the last thing done
before connection of pipes and commissioning
of the cylinder.
This manual gives detailed advice for installation
and should be read carefully prior to fitting any
unvented unit. OSO Slimline cylinders are not
suitable for gravity fed primary systems. In known
hard water regions, precautions should be tak-
en to prevent limescale formation in hot water
cylinders, in accordance with Building Regulation
Part L, Domestic Heating Compliance Guide.
This OSO cylinder must be installed by
a competent person and be installed in
compliance with the OSO Installation and
Maintenance Instructions, all current legislation,
codes of practice and regulations governing the
installation of unvented hot water cylinders in
force at the date of installation.
Directive: 2009/125/EC
Model/identifier
!
CAUTION
Regulation: EU 814/2013
ErP
Heat
Storage
Rating
loss W
volume L
C
76
141