2.6

DDC function, check of asset management

This writing operation should be carried out with the service tool (refer to the followings for
detail of service tool).
The version of the service tool software used is as follows.
Service tool S/W folder name: SVT312NM211
Service tool S/W version: Ver3.12-2.1-1
Be sure to read "Read me first" first in using the service tool.
For concrete use, refer to the service tool manual attached to the service tool.
Lower 5 digits of S/N   →  converted to hex. Numbers   →  registered in ascending order
Upper 3 digits of S/N   →  0 (according to VESA standard)
(Ex.) 512002978  →  00000BA2  →  Models having  
[ASCII conversion]
Using the barcode system read the serial numbers (9 digits) assigned at NMV (Nagasaki), then establish the serial
 number through the following conversion.
S/N  →  converted to ASCII code  →  registered (to Monitor Descriptor #4) in descending order
(ex.) 512A02978
                ↓
35 31 32 41 30 32 39 37 38 
                ↓
Models having        Models having
NO ASSET function     ASSET function
MPU side          Dedicated EEPROM side      Data (H)
Address (H)         Address (H)
E81              71                 35
E82              72                 31
E83              73                 32
E84              74                 41
E85              75                 30
E86              76                 32
E87              77                 39
E88              78                 37
E89              79                 38
E8A           7A              0A → shows the end of S/N data*
E8B           7B              20 → shows blank*
E8C           7C                                                  20 → shows blank*
E8D           7D                                                  20 → shows blank*
         
      
              *Fixed data (set according to the number of digits of S/N)
 NO ASSET function      ASSET function
MPU side        Dedicated EEPROM side     Data (H)
Address (H)       Address (H)
78C             0C                                  A2
78D                                       0D                                  0B
78E           0E                                  00
78F                                        0F                                  00
2 - 33