Adjustment
Adjustment item name
order
4V-COIL
10
PQV-TL
PQV-TR
11
12
PQV-BL
13
PQV-BR
*
Specify the adjustment value range of the following adjustment items in general DDCP
adjustment.
Adjustment
Adjustment item name
order
6H-COIL
1
DDCP-6H-DC
Adjustment items
• CONVERGENCE (HOR.)
• CONVERGENCE (VER.)
• YHJT
• YHJB
Problem
B
R
Problem
R/B
G
Adjustment value range (Factory mode))
2Bh (43) - D3h (211) (OSM display value=DAC output value)
2Bh (43) - D3h (211) (OSM display value=DAC output value)
Dh (13) - F1h (241)
Dh (13) - F1h (241)
2 - 22
Adjustment point
PQV (Top Left)
PQV (Top Right)
PQV (Bottom Left)
PQV (Bottom Right)
Adjustment point
Adjustment procedure
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
Adjust to 0.3mm or less.
Adjustment procedure
Adjust to 0.05mm or less.
(Adjustment target is 0mm.)