1. Electrical inspection
1.1 Electrical performance
Function switch check
1) Input 1024×768 (75Hz) pattern "Crosshatch".
2) Image should appeared within 4sec after Switch ON.
3) LED lighting green.
4) It should not appear noise while Switch is turn ON or turn OFF.
5) OSM should be indicated by push [Exit] or [<] OR [>] or [-] or [+] button.
6) While [-] or [+] button is pushed, the value should change smooth and it should not be appeared noise.
7) Check the OSM off when push the [OSM OFF] switch EXIT.
1.2 Frequency change
1) Change the preset timing.
2) Check the picture and the time when freq. change (less 5 sec).
1.3 Performance check
1) Input 1024×768 (75Hz) pattern "RGB 256 GRAY SCAL" PATTERN.
2) Press [AUTO CONTRAST] switch.
3) Check the color gray scal smoth and not data lost.
1.4 Check power manage function
Mode
Normal
Standby
Suspend
Off
Horizontal
Vertical
On
On
Off
On
On
Off
Off
Off
Power
Input Timing
Supply
240V
1024×768 (75Hz)
240V
1024×768 (75Hz)
240V
1024×768 (75Hz)
240V
1024×768 (75Hz)
5-2
Power
consumption
20W
2W
2W
2W