Storage; Ports & Devices - Axis C8033 User Manual

Network audio bridge
Hide thumbs Also See for C8033:
Table of Contents

Advertisement

AXIS C8033 Network Audio Bridge
About system options
Traps for SNMP v1/v2 are used by the Axis product to send messages to a management system on important events and status
changes. Check Enable traps and enter the IP address where the trap message should be sent and the Trap community that
should receive the message.
The following traps are available:
• Cold start
• Warm start
• Link up
• Authentication failed
SNMP v3 provides encryption and secure passwords. To use traps with SNMP v3, an SNMP v3 management application is required.
To use SNMP v3, HTTPS must be enabled, see HTTPS on page 26. To enable SNMP v3, check the box and provide the initial user
password.
Note
The initial password can only be set once. If the password is lost, the Axis product must be reset to factory default, see How
to reset to factory default settings on page 34.
UPnP
The Axis product includes support for UPnP
systems and clients that support this protocol.
UPnP can be disabled under System Options > Network > UPnP.
Bonjour
The Axis product includes support for Bonjour. Bonjour is enabled by default and the product is automatically detected by operating
systems and clients that support this protocol.
Bonjour can be disabled under System Options > Network > Bonjour.

Storage

You can record and store your videos either on a network storage, such as a NAS (network-attached storage) or on an onboard storage.
Ports & Devices
I/O Ports
The Axis product provides two configurable input and output ports for connection of external devices.
To configure the I/O ports, go to System Options > Ports & Devices > I/O Ports. Each port can function as input or output:
• Input as Open circuit – The input becomes active when the circuit is grounded by. It remains inactive as long as its
normal state equals its current status.
• Input as Grounded circuit – The input becomes active when the circuit is opened.
• Output as Open circuit – The output port is in a non-conductive state when its current status is open circuit. The current
status of an output port can be changed by, for example, an action rule.
• Output as Grounded circuit – The output port is in a conductive state when its current status is grounded circuit.
®
. UPnP is enabled by default and the product is automatically detected by operating