Troubleshooting; Additional Items - Eastwood HYDRAULIC TUBING BENDER Instructions Manual

Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
CAUSE
Does Not Run
When Switch
No power to Hydraulic Pump Motor
is Turned On
Motor Runs
Excessive voltage drop due to under-
Too Slow/
sized and or too long of an extension
Develops Low
cord used
Power
Low fluid level in Reservoir
Tripped Circuit Breaker
Cylinder Stops
Before Bend is
Obstruction or binding of components
Completed
Material wall thickness too great and
has exceeded the maximum 0.120"
[3mm] @ 2" wall thickness capability of
the machine

ADDITIONAL ITEMS

#21118
1.0" x 4" Radius, 120° Die
#21119
1.5" x 5" Radius, 120° Die
#21120
1.625" x 5" Radius, 120° Die
#21121
1.75" x 6" Radius, 120° Die
#21122
2" x 6" Radius, 120° Die
#21124
1.0" x 4" Radius, 240° Die
#21125
1.5" x 5" Radius, 240° Die
#21126
1.625" x 5" Radius, 240° Die
#21127
1.75" x 6" Radius, 240° Die
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.343.9353 >> email: tech@eastwood.com
PDF version of this manual is available at eastwood.com
The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA 800.343.9353 eastwood.com
© Copyright 2019 Eastwood Automotive Group LLC
CORRECTION
Check 120 VAC input plug connection.
Check for tripped circuit breaker. The Pump Motor operates on a 15 Amp
Minimum circuit.
Extension cords not recommended. If necessary, use only 14 Gauge or larger
cord and limit length to 25'.
Retract cylinder fully and check fluid level. Add a high quality, 10w hydraulic oil
as needed.
Check for tripped circuit breaker. The Pump Motor operates on a 15 Amp
Minimum circuit.
Retract cylinder and check thoroughly for any obstructions or binding of
components.
Retract cylinder and re-evaluate material selection.
10/19
Instruction item #22199Q
Rev 1

Advertisement