Foam Soap Dispenser Troubleshooting and Maintenance
Nozzle
Sensor
Part number: 08002337
AUX connectors
Inlet pipe
Outlet pipe
Compressor
Part number: 07222010
Pump
Part number: 07222028

Advertisement

loading
Need help?

Need help?

Do you have a question about the EZ-FILL and is the answer not in the manual?

Questions and answers

Summary of Contents for ASI EZ-FILL

  • Page 1 Foam Soap Dispenser Troubleshooting and Maintenance Nozzle Sensor Part number: 08002337 Outlet pipe AUX connectors Compressor Part number: 07222010 Pump Part number: 07222028 Inlet pipe...
  • Page 2 Indication Investigation Cause Solution Illustration False activation: Continuous discharge from AUX connector not The connector should be inserted Foam dispensing the nozzle fully inserted fully until white o-ring is not visible. Remove the o-ring if necessary O-RING VISIBLE – NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE –...
  • Page 3 Indication Investigation Cause Solution Illustration Foam not Pump and compressor are making Tip of inlet pipe is not Ensure that the tip of the inlet dispensing a sound when sensor is activated immersed in soap pipe is fully immersed in the soap. For earlier models check that the Multifeed units only pipe has not been pushed so far...
  • Page 4 Indication Investigation Cause Solution Illustration Foam not Pump is not Sensor is not Refill button on pump Transformer: Check operation dispensing making sound blinking when does not activate the with functioning transformer. when the sensor hand is placed pump. Where necessary replace with is activated in front appropriate transformer.