Please Read This First Getting Started with Schick AE For complete details about your Schick AE system and the latest software, please visit our website at http://dsgo.to/schick...
The Schick AE system acquires intraoral X-ray images and transmits them by USB connection to desktop or laptop PCs. There are two main devices in the system: the Schick AE Sensor, which acquires the intraoral X-ray images and the Schick AE Sensor USB Interface (also referred to as the USB Interface in this document), which sends the images by USB cable to the PC.
Page 3
Connects to laptop or desktop PC USB port or hub Connection status LED Schick USB Cable Sensor Status LED Schick AE Sensor USB Interface Schick AE Sensor Schick AE Connections and LED Indicators Getting Started with Schick AE Page 3...
» Please type the following link http://dsgo.to/schick into your browser, press Enter, and click on the Schick AE and Sensors link to download the latest driver and firmware for the Sidexis 4 Sensor Plugin. » Follow the on-screen instructions until installation is complete.
Page 5
Installation (continued) Connect the AE Sensor and USB Interface » Connect the Schick AE Sensor cable to the USB Interface. » Connect the USB cable to the USB Interface. » Click on the Devices link on the configuration page. NOTE: If the Devices link isn’t shown, clear your browser cache and refresh the page.
USB Interface is connected and Connected AMBER powered but no connection to imaging software is detected. GREEN Connected Ready for acquisition. “breathing” Sidexis server not configured GREEN Connected (from Sensor Plugin Configuration “pulsing” page). Page 6 Getting Started with Schick AE...
Page 7
Sidexis 4 (or connected other imaging program). Error condition, such as Connected AMBER incompatible sensor. Schick AE Sensor and USB Interface are connected. Sidexis is configured properly and has Connected GREEN detected the USB Interface. Start Sidexis 4 (or other imaging program).
Page 8
These settings are applied at display time and do not affect the original image data. Clinical tasks can be changed for any Schick AE Sensor image, from one task to another, and back at will.
Page 9
Save As Default button. Selecting Diagnostic Tasks Changing the Default Sharpeness For more information Please refer to the Schick AE operating instructions on our support site. Getting Started with Schick AE Page 9...
Do Not Connect Items that are Not Part of the System Only items specified for use with the Schick AE Sensor and USB Interface are to be connected to it. The device should not be used adjacent to other equipment that is not part of the system.
Page 11
Only Dentists or Authorized Designees Are Permitted to Operate the System To ensure the correct use of the Schick AE Sensor and USB Interface in a clinical environment, for purposes that correspond to its intended design and application, only dentists, or their designees, are authorized to operate the system.
Page 12
Safety and Compliance (continued) Protect Sensor from Potential ESD Damage Like other electronic devices, your Schick AE Sensor is susceptible to electrostatic discharge (ESD), particularly when the device is used in or around carpeted areas or low-humidity environments. During cable replacement, when Sensor contacts are exposed, it is especially important to protect the device from potential ESD damage.