Table of contents Dentsply Sirona Instructions for Use SiroCam UAF Plus Table of contents General information ....................Dear customer......................Contact information ....................Scope of these instructions for use ................. About these instructions for use................1.4.1 General information .................. 1.4.2 Conventions .....................
Page 3
Dentsply Sirona Table of contents Instructions for Use SiroCam UAF Plus Cleaning........................Handpiece ....................... Lens surface......................Cleaning products ....................Technical data ......................Optical ........................Physical........................Electrical........................Ambient ........................Electromagnetic compatibility ................. Electromagnetic emission ..................Interference immunity....................Working clearances....................Interference......................Error messages.......................
● Easily portable between operatories. These Operating Instructions are designed to assist you prior to initial use and whenever you require information later on. We wish you a great deal of success with the SiroCam UAF Plus. Your SiroCam UAF Plus Team Contact information...
Dentsply Sirona 1 General information Instructions for Use SiroCam UAF Plus 1.4 About these instructions for use About these instructions for use 1.4.1 General information Read the document Please familiarize yourself with the intraoral camera and its software by reading through these instructions for use before putting it into operation.
1 General information Dentsply Sirona 1.4 About these instructions for use Instructions for Use SiroCam UAF Plus 1.4.3 Identification of the danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in these instructions for use.
Requirements 1.6.1 Operating systems SiroCam UAF Plus is compatible with Sidexis 4.2 or higher. Sidexis 4.2 is compatible with the following operating systems: ● Windows 10 Professional (64-bit) ● Windows 8.1 Professional (64-bit) 1.6.2...
2 Safety Dentsply Sirona 1.6 Requirements Instructions for Use SiroCam UAF Plus Safety Check the Camera before Using It There are no customer-serviceable components in the camera. However, before each usage, check the outer surface of the camera for any signs of physical damage or defect. The surface of the camera should have a smooth finish, with no evidence of chipping or damage to either the handpiece housing or the lens section.
Continuous operation 49 °C 57 °C Symbols Dentsply Sirona products display markings to indicate compliance with regulatory requirements and applicable technical standards: Indicates Type BF device in accordance with applicable medical safety standards (IEC/EN/UL 60601-1). Indicates an attention to customers to consult accompanying documents for information needed for proper use of device.
2 Safety Dentsply Sirona 2.2 Disposal Instructions for Use SiroCam UAF Plus This product bears the CE mark in accordance with the provisions of the Regulation (EU) 2017/745 of April 5, 2017 concerning medical devices. This product is a medical device.
ü The camera is not connected to the PC. 1. Log onto your PC with an administrator account. 2. Insert the "SiroCam UAF Plus" CD into your PC's CD/DVD drive. 3. Browse for the "Sidexis Video Modules" setup folder and open it.
Page 12
3 Installation Dentsply Sirona 3.1 Install Sidexis 4 video modules Instructions for Use SiroCam UAF Plus 7. When setup is complete, click Finish. 66 90 6 43 D3762 D3762.201.01.03.02 04.2021...
ü The camera is not connected to the PC. ü You are logged into your PC with an administrator account. ü The “SiroCam UAF Plus” CD is in your PC’s CD/DVD drive. 1. Browse for the “Sirona UAF Plus Module” setup folder and open it.
Page 14
3 Installation Dentsply Sirona 3.2 Install Sirona UAF Plus module Instructions for Use SiroCam UAF Plus 5. When setup is complete, click Finish. 66 90 6 43 D3762 D3762.201.01.03.02 04.2021...
3.3 Update firmware Update firmware The update of the SiroCam UAF Plus firmware is described in the Instructions for use "Dentsply Sirona Sivision TWAIN" REF 67 1 6 1 17. Install the TWAIN software intended for the camera first, see chapter "Installation".
4 Operation Dentsply Sirona 4.1 Prior to initial use Instructions for Use SiroCam UAF Plus Operation Prior to initial use Before using the camera for the first time, make sure you have cleaned it thoroughly. Procedures for cleaning the camera handpiece and the lens surface can be found in the “Cleaning”...
Dentsply Sirona 4 Operation Instructions for Use SiroCam UAF Plus 4.4 Camera options Camera options 4.4.1 Turning the camera on or off If the camera is off, perform any of the following actions to turn the camera ON: ● Remove the camera from its holder.
4 Operation Dentsply Sirona 4.5 Protective sheaths Instructions for Use SiroCam UAF Plus Protective sheaths To place protective camera sheaths, perform the following steps: ü New camera sheath is available. 1. Holding the camera with the lens surface facing down, insert the camera into the protective hygienic sleeve.
2. Press and hold the camera handpiece button down for about one second. 3. Click on the SiroCam UAF Plus image in Sidexis 4. Ä The camera will auto-focus automatically during operation. When positioning the camera, find an optimal distance from the object or image area.
Dentsply Sirona 4 Operation Instructions for Use SiroCam UAF Plus 4.9 Save or discard images in Sidexis 4 Save or discard images in Sidexis 4 As still images are captured, they accumulate in a vertical column next to the video window. Depending on the Video Plugin setting for marking images, they are set initially to be saved or discarded.
4 Operation Dentsply Sirona 4.9 Save or discard images in Sidexis 4 Instructions for Use SiroCam UAF Plus 4.9.2 Discarding images To select images to be discarded, perform the following step: ü Captured still images are available. ➢ If the images are already selected to be discarded, meaning that they are shown with “X”...
Dentsply Sirona 4 Operation Instructions for Use SiroCam UAF Plus 4.9 Save or discard images in Sidexis 4 4.9.3 Changing selections If you wish to save one or more images and discard the rest, perform the following steps: ü Captured still images are available.
4 Operation Dentsply Sirona 4.10 Video window controls Instructions for Use SiroCam UAF Plus 4.10 Video window controls The video window controls, and the settings in Video Plugin Options, determine how images are saved or discarded at the end of the video session.
Dentsply Sirona 4 Operation Instructions for Use SiroCam UAF Plus 4.11 Video options 4.11 Video options Settings are available in Sidexis 4 to provide different ways of managing the video window and saving images. ü Sidexis 4 is running. 1. Click on the Settings (gear) icon.
5 Cleaning Dentsply Sirona 5.1 Handpiece Instructions for Use SiroCam UAF Plus Cleaning Handpiece Before using the camera the first time, and before every new patient, the following protocol is recommended: 1. Remove and discard all protective hygienic barriers and / or sheaths from the camera prior to removing disposable gloves.
Dentsply Sirona 6 Technical data Instructions for Use SiroCam UAF Plus 6.1 Optical Technical data Optical Lighting Lens Auto-focus Sensor technology ¼-inch CMOS Resolution (pixels) 1276 x 796 Depth of field (mm) 2 to 130 Magnification x250 (maximum) Viewing angle (degrees) 90°...
6 Technical data Dentsply Sirona 6.4 Ambient Instructions for Use SiroCam UAF Plus Ambient Transport and storage conditions Temperature -40° C to +70° C Relative humidity (%) 10 to 95 Atmospheric pressure (hPa) 500 to 1060 Operating conditions Temperature +10° C to +40° C...
EMC aspects. SiroCam UAF Plus complies with the requirements for electromagnetic compatibility (EMC) according to IEC 60601-1-2:2014 SiroCam UAF Plus is designed for use in professional healthcare facility environment. SiroCam UAF Plus is referred to in the following as "UNIT".
7 Electromagnetic compatibility Dentsply Sirona 7.2 Interference immunity Instructions for Use SiroCam UAF Plus Interference immunity Enclosure port Phenomenon Basic EMC standard Interference immunity test level for profes- or test method sional healthcare facilities Electrostatic discharge IEC 61000-4-2 ± 8 kV contact ± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air Radiated RF electromagnetic fields IEC 61000-4-3...
Page 31
Dentsply Sirona 7 Electromagnetic compatibility Instructions for Use SiroCam UAF Plus 7.2 Interference immunity Ports of signal input/signal output units (SIP/SOP) Phenomenon Basic EMC standard Interference immunity test level for profes- sional healthcare facilities Electrostatic discharge IEC 61000-4-2 ± 8 kV contact ± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air Connectors shall be tested per 8.3.2 and Table 4 of IEC...
7 Electromagnetic compatibility Dentsply Sirona 7.3 Working clearances Instructions for Use SiroCam UAF Plus For some radio services, only the frequencies for the radio link between the mobile communication device and the base station (uplink) have been recorded in the table.
PC workstation NOTE: If the above actions do not resolve your issue, please contact a Dentsply Sirona support representative or an authorized dealer for further assistance. 66 9 0 6 43 D3762 D3762.201.01.03.02 04.2021...