3. LoRaMoteConfig Functionality

Most parameters related to the implementation of a sensor connected to a LPWAN network following the LoRaWAN R1.0
specification, can be modified by the PC application for later use in a stand-alone fashion. They are stored in the E2PROM
of the host microcontroller.

3.1 Saving and Restoring Parameters

Figure 3-1: Control buttons
Write: Writes the current configuration to the EEPROM
Read: Reads the current configuration from the EEPROM
Defaults: Resets the configuration to its default values
Reset: Resets the LoRaMote. The new configuration is only applied once the LoRaMote has been reset.

3.2 Activation Tab

Figure 3-2: Activation Tab
Activation method (OTAA or Personalization) can be selected here. Depending on the chosen method, parameters can be
modified:
OTAA: AppEUI and AppKey. An automatically-calculated AppKey is proposed to simplify the process, and will be
unique to each DevEUI
Personalization: AppSKey and NwkSKey can be programmed here