Egress control and open connector (IN and OUT)
You can optionally use the IN and OUT terminals for egress
control and door relay operation.
IN. An egress button (normally open, momentary push-
button switch) can be connected across the IN and 0V
terminals (Figure 7). When pressed, the button
controls the request-to-exit function to the panel.
Out. Open collector output must be assigned with a
number according to the output controller selected.
Use the first output control assigned to the unit. Refer
to the control panel programming manual for details.
Note:
An external UL Listed power supply is required for UL
installations.
Figure 7. Optional IN and OUT terminals
Keypad power
from panel LAN
+12
0V
Egress
D+
D-
IN
OUT

LED indications

The unit provides both system status and area LEDs.
Status LEDs
The unit has four status LEDs located above the LCD screen
(Figure 1 on page 1) that indicate that following:
Power (green LED). The green LED illuminates when the
control panel is powered by the AC supply.
Fault (yellow LED). The yellow LED illuminates to indi-
cate detection of a system fault.
Access (blue LED). The blue LED flashes when access to
an area assigned to the unit is granted. It also flashes
once when a card is badged at the AL-1116 (subject to
valid card flashing programming).
Alarm (red LED). The red LED illuminates when there is
a system tamper or an area assigned to the unit is in
alarm state. To identify the area, view the 16 area
LEDs hidden by the cover (Figure 1 on page 1). See
Area
LEDs.
Area LEDs
When the unit cover is opened or removed, 16 LEDs are visible
below the keypad (Figure 1 on page 1). Each LED represents an
area and indicates the following:
• Red LED illuminates when its corresponding area is armed.
• Red LED flashes when a fault is detected in its corre-
sponding area.
• Green LED illuminates when the corresponding area is
disarmed and ready to arm.
• No illumination indicates the corresponding area is
disarmed but not ready to arm.
External door
0V
lock power
+12
source
To door
strike
solenoid
Door control
relay

Operating features

The unit includes the following features:
Keyboard backlight and night light. By default the
keyboard backlight is on (bright) for approximately
4.15 minutes following a key press. The night light by
default is on (dim). To change these options, see
options
on page 4.
LCD contrast. To adjust the LCD contrast, press and hold
the Menu key (Figure 1 on page 1) while you press the
Up or Down keys (Figure 8). The default setting is 12.
Figure 8. Keys
Bypass/instant key
Unused key
Down key
Bypass/instant key. To bypass active zones when you arm
the system, press the Bypass/instant key (Figure 8).
You can also use this key for instant arming. To use
instant arming, enter the user PIN and press the
Bypass/instant key.
Stay key. Use the Stay key (Figure 8) when you are arming
the system to autobypass the interior zones and arm all
the perimeter zones for access.
LCD backlight. The LCD backlight illuminates for 30
seconds following a key press.
Beeper tone. To adjust the beeper tone, press and hold the
Clear key (Figure 1 on page 1) while you press the Up
or Down key (Figure 8). The default setting is 16.
LCD text format. The 4 line by 16 character LCD can
display text in the following formats:
Format 1 (default) wraps text using hyphens
when a word is broken onto the next line.
Format 2 wraps text without hyphens when a
word is broken onto the next line.
Format 3 wraps text to the next line without
breaking words.
To change the format, press and hold the 0 key while
you press the Up or Down key.
Card reader (AL-1116 only). The AL-1116 is fitted with a
Smart Card reader that uses the address of the unit to
communicate with the panel and so does not need its
own system bus address. The reader is located behind
the keypad with the number 2 key being the approxi-
mate center (Figure 1 on page 1). The sensitivity of the
reader depends on the mounting environment (large
metal surface will reduce the reader's sensitivity).
Up key
Stay key
Unused key
3
Menu