Si12-891
Step
11
Release the discharge
pipe thermistor.
12
Disconnect the
connector for the
thermistors [S90].
13
Detach the clamp for
the thermistors from the
electrical box.
Remove the screw on
14
the right side of the
electrical box.
Removal Procedure
Procedure
Discharge pipe thermistor
[S90]
Removal of Electrical Box
Points
Meet the edge of the
thermistor and the clip.
Be careful not to lose the clip
for the thermistor.
(R12535)
[S90]: thermistors (outdoor
temperature, outdoor
heat exchanger,
discharge pipe)
(R7587)
Clamp
(R12771)
(R12536)
7