3-6. Water leaking

Forecast of cause
Diagnosis method when water leak occurs
Is main unit installed in stable condi-
tion?
Is main unit broken or deformed at the
time of transportation or maintenance?
Is drain hose connection loose?
Is there a trap in drain hose?
Is drain hose clogged?
Is fan rotating?
End
3-6. Water leaking
Erroneous installation
Drain hose failure
Diagnosis method when water is spitting
Is the filter clogged?
Check gas pressure and cor-
rect it if there was a gas leak.
- (03-42) -
out
MPa MPa
End