Fujitsu ASUG09LZAS Service Manual page 133

Wall mounted type, refrigerant r410a inverter, indoor/outdoor
Hide thumbs Also See for ASUG09LZAS:
Table of Contents

Advertisement

¢ Sleep timer
If the sleep timer is set, the room temperature is monitored and the operation is stopped auto-
matically. If the operation mode or the set temperature is change after the sleep timer is set, the
operation is continued according to the changed setting of the sleep timer from that time on.
• In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 1°C. It increases the setting
temperature another 1°C after 1 hour. After that, the setting temperature is not changed and
the operation is stopped at the setting time.
• In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 1°C. It decreases the setting
temperature another 1°C every 30 minutes. Upon lowering 4°C, the setting temperature is not
changed and the operation is stopped at the setting time.
¢ Weekly timer
On and off timer can be combined, and up to 4 reservations per day and 28 reservations per
week. Before setting the program, set the week and time of the air conditioner at first. If the week
and time are not set, the weekly timer will not operate correctly at the setting time.
5-2. Wired remote control
Set temperature rises
+2°C
+1°C
Ts
Set
Set temperature rises
Ts
-1°C
-2°C
-3°C
-4°C
Set
30 min
30 min
- (04-21) -
Stop of operation
60 min
Ts: Set temperature
Stop of operation
30 min
Ts: Set temperature
5. Timer operation control