Description Of The Appliance - Accorroni GTF Series Installation, Use And Maintenance Manual

For use with a second energy source
Table of Contents

Advertisement

1
D.H.W. HEATER CATEGORY
These devices are classified as generator of hot water with sealed
combustion chamber and atmospheric burner.
They are classified in the category II2H3+,it means that they can be
used with the gas of second class: natural, methane H and of third
class Lpg butane, propane.
As for the European norm EN 483 they are identified referring with
the system for air aspiration and fumes drain C13,C23,C53.
2
PACKAGING
���
���
����
Mod.
N. pack
Dimensions (h x l x p) (mm)
220
1
300
1
400
1
500
1
800
1
2150 x 1100 x1100
The water heater is supplied in a case of wood, with one envelope,
in the frontal containing the present manual and the certificate of
guarantee.
APRIL 2009 Issue (Italy)

DESCRIPTION OF THE APPLIANCE

Fig. 01
Weight (Kg)
1650 x 780 x 780
2000 x 780 x 780
1800 x 820 x 820
2080 x 820 x 820
3
DESCRIPTION OF THE WATER HEATER
The water heater is composed from a water tank lodged over to
a combustion chamber where the heat necessary is developed in
order to heat the water.
The produced smoke therefore yields their heat to the water in
their fireplace towards the outside, passing through the tubes, the
exchanger dipped in the water.
On the high part a canopy collects the fumes from the exchanger and
drives them to the drainage system. A fan is situated in the upper
cap it, supplies the feeding of the air and the evacuation of the
products of combustion. The tank is constructed in sturdy sheet iron
and guarantees a remarkable resistance to pressure it's moreover
glass lined at 860°. This concurs to obtain an optimal unassailable
chemical resistance (from organic solvent and from chemical
substances), an optimal thermal stability; the enamel resists until
500° The inner inspection and cleaning from the incrustations is
possible through the flange 120 mm diameter.
The combustion chamber is placed in the low part of the water
heater and it contains the atmospheric burner and flame probes.
Combustion chamber is completely sealed from the place where it
is installed.
Control Panel
The control panels contains all the components in order to adjust
the normal operation of the water heaters: thermostat, ignition
device, luminous release button, thermometer etc..
KIT OF SMOKE DRAINAGE (supplied separately)
As for the different requirements of Installation it can be:
• Concentric with drainage and aspiration to the wall
• Concentric with drainage and aspiration to the wall
• Divided with drainage and aspiration to the wall, to the roof or
160
in a fume pipe.
187
200
232
335