Accorroni GTF Series Installation, Use And Maintenance Manual

For use with a second energy source

Advertisement

Quick Links

INSTALLATION, USE AND
MAINTENANCE MANUAL
GTF SOL SERIES
FOR USE WITH A
SECOND ENERGY SOURCE
Storage gas water heaters with forced
and sealed conbustion chamber, assisted gas fan
0051
MOD. 220
MOD. 300
MOD. 400
MOD. 500
MOD. 800
GTF SERIES
MOD. 220
30 kW
MOD. 300
34kW
MOD. 400
34kW
MOD. 500
34kW
MOD. 800
34kW
APRIL 2009 Issue (Italy)

Advertisement

Table of Contents
loading

Summary of Contents for Accorroni GTF Series

  • Page 1 INSTALLATION, USE AND MAINTENANCE MANUAL GTF SERIES MOD. 220 30 kW MOD. 300 34kW MOD. 400 34kW MOD. 500 34kW MOD. 800 34kW GTF SOL SERIES FOR USE WITH A SECOND ENERGY SOURCE MOD. 220 MOD. 300 MOD. 400 MOD. 500 MOD.
  • Page 3: Description Of The Appliance

    DESCRIPTION OF THE APPLIANCE D.H.W. HEATER CATEGORY DESCRIPTION OF THE WATER HEATER These devices are classified as generator of hot water with sealed The water heater is composed from a water tank lodged over to combustion chamber and atmospheric burner. a combustion chamber where the heat necessary is developed in They are classified in the category II2H3+,it means that they can be order to heat the water.
  • Page 4: Magnesium Anode

    must be executed from qualified staff. TEST OF THE WATER HEATER AND SECURITY In case of replacement of the valve be sure that the flow of the gas Electronic ignition card is in compliance with the arrow on the body of the valve and that during the assembly operations external substances do not enter.
  • Page 5 ø 6 4 5 OVER PRESSURE VALVE CONTROL PANEL The function of this device is to permit the water flow out from the drain hole of the valve in case that pressure inside the tank increases. � A Switch on/off key B Adjustment thermostat �...
  • Page 6 WATER HEATER DIMENSIONS, WATER AND GAS CONNECTIONS Fig. 09 GTF-GTF SOL Total height 1600 1950 1766 2036 2146 Height of body 1265 1615 1430 1700 1810 Base width 1010 Water heater diameter 1000 Water drain 3/4” Cold water inlet 1” 1/4 Recirculation 1”...
  • Page 7 ���������� ��������� ����� ������ FLUE GAS VENTS ���������������� Cod. A 01.001.000648 Accessories: PRODUCT NO. DESCRIPTION ����� A 01.001.000278 Coaxial extension pole Ø 60/100 1 mt ����� ���������� A 01.001.000276 Coaxial elbow Ø 60/100 90° not flanged ����� ���������������� ��������� ��������� GTF 068 Air diaphragm Ø...
  • Page 8 ���������������� Accessories: ���������� CODE DESCRIPTION A 01.001.000278 Coaxial extention pole Ø 60/100 1 mt ����� A 01.001.000276 Coaxial elbow Ø 60/100 90° smooth ended �� ���������������� A 03.001.000602 Flanged Coaxial elbow Ø 60/100 90° for COAXIAL KIT TO ROOF connection with the water heater Cod.
  • Page 9: Technical Data

    TECHNICAL DATA TECHNICAL DATA FOR GTF GAS WATER HEATER MODEl unit CAPACITY litres NOMINAL THERMIC CAPACITY NOMINAL THERMIC POWER 26,8 30,6 30,6 30,6 30,6 COMBUSTION EFFICIENCY OPERATING TIME AT 25° OPERATING TIME AT 45° SINglE wATER DRAwINg AT 25°C litres 1100 1760 SINglE wATER DRAwINg AT 45°C...
  • Page 10: Pannello Di Comando

    ELECTRIC DIAGRAM SCHEMA ELETTRICO While connection the cable to the electric power respect the polarity of the net /phase-neutral). In case of wrong connection or polarity the Nel collegare il cavo di alimentazione alla rete elettrica, rispettare la polarità della rete (fase - neutro). In caso di polarità invertite o di water heater does not work.
  • Page 11 ������������������������������������������ �������� ��������������� ��������������������������� �������������������������������� �� �� PARTS SCHEME �������� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� ������� �� ��...
  • Page 12: List Of Components

    ��������������� ����� ������� ����� ������������������������������������������ LIST OF COMPONENTS ������� ��������������������������� ���������������� �������������������������������� CODE DESCRIPTION CODE DESCRIPTION Thermometer with probe Electrode Carter Ignition electrode Control panel Turbolator bracket Green light operation Turbolator 220L À À Ignition key Turbolator 300L Thermostat knob Turbolator 400L Red light with reset Turbolator 500L...
  • Page 13: For The Installer

    FOR THE INSTALLER The installation must be made from qualified staff as for the regulation in force, in a position to assuring the starting and the test. Pay attention to the choice of the model is for of the requirements of water production, see the values of water production in the scheme of the technical data.
  • Page 14: Plumbing Connections

    TERMINAL DISTANCES Under window Under ventilation opening Under the eaves Under the balcony From adjacent window From opening of adjacent ventilation From pipes From pipes From a recess From the floor 2500 Between two vertical terminals 1500 Between 2 horizontal terminals 1000 From a front surface without opening or terminals in a 3 mt ray from fumes outlet 2000...
  • Page 15: Gas Circuit

    Burner calibration pressure with methane GAS CIRCUIT While the product is in function, use a screw driver to turn the screw Connect the gas with the threaded connection using a rigid RP to obtain the pressure as below. connector that can be disassembled. Stop the burner and switch on it after some seconds.
  • Page 16 Modification from LPG to methane ANOMALOUS OPERATION 1. Verify that diameter of the injector supplied in the kit corresponds The control equipment goes in block without to command to the model for LPG. to the ignition. 2. Close the gas interception tap and switch off the electricity. •...
  • Page 17 From this moment begins the cycle of ignition of the generator. IGNITION The pressure created from the expulsion fan fumes closes the 1. Press the button of ignition contacts of the pressostat and the co the consent for the troll unit 2.
  • Page 18 NOTE...
  • Page 20 A2B Accorroni E.G. s.r.l. Via d’Ancona, 37 - 60027 Osimo (An) - Tel. 071.723991 r.a. - Fax 071.7133153 web site: www.accorroni.it - e-mail: a2b@accorroni.it...

Table of Contents