Page 3
3 The A2B Accorroni E.G. LTD accepts no responsibility for any damage caused by improper use, to a use other than that prescribed and by an incomplete or approximate application of the instructions contained in this manual.
INDEX MAIN FEATURES ........................5 1.1 Classification of fittings ....................... 5 1.2 Certifications - CE ........................ 5 Design features ........................... 5 Contents of the packaging ......................5 Accessories supplied on request ....................5 Application ........................... 5 Safety Standards.......................... 6 GENERAL SAFETY ........................6 2.1 Installer Qualification ........................ 6 Power supply ..........................
or two convection fans axial type with safety grille. 1.0 MAIN FEATURES The fan motors are single-phase with external rotor, This manual collects the installation standards, proper designed for different operating speeds, using special use and maintenance of the HEATERS series LC. auto-transformer.
damage to persons, animals or things caused by - do not to proceed to clean the outer parts of the nonobservance of this manual, by modifications appliance without first removing the power supply or tampering with the product, to errors in at the main switch; installation, adjustment, maintenance - do not leave the appliance exposed to the...
environment or leave them within reach of children 4.0 INSTALLATION as they are potentially dangerous. The possible storage of the unit, must take place in 4.1 GENERAL INFORMATION - POSITIONING a suitable place, away from atmospheric agents and Before carrying out any installation work, ensure that from excessive moisture, for the shortest possible the following conditions are met: time.
Possible Shutdown . It is banned the use of gas and / or water pipes for the fixing of the unit on the ground. A2B Accorroni is not responsible of any damage caused by lack of With this provision it is aimed to obtain a circular air...
Wanting to increase vertical launch it can be done in Positioning air blowers so that the interfering influence zones between them thus obtaining a decrease of the braking action Air jet lands on its activation and a fig . 6 . The heaters of the LC series can be provided with support brackets , which facilitate the positioning in place Fig .
6.0 WATER CONNECTION 7.0 ELECTRICAL CONNECTIONS WARNING! Make the electrical connections The sizing of the water supply must be done according with power off and only after completing the to the instructions of the designer. The heaters are plumbing connections and have verified the proper provided with threaded connections listed in the tables maintenance .
9.0 WIRING WIRING LC 16 / 20 / 28 BASE LEGEND M = Clamp C = Condensator b = Blue m = Brown n = Black gv = Yellow- green Mv = Motor fan Fig. 10 Connections to be made..... WIRING LC 16 / 20 / 28 WITH CONSENT THERMOSTAT...
Page 15
16 / 20 / 28 WIRING LC WITH AMBIANCE THERMOSTAT winter mode To take off the bridge between 0 and 4 Fig. 12 Connections to be made..... WIRING LC 16 / 20 / 28 WITH AMBIANCE THERMOSTAT, SUMMER MODE (VENTILATION ONLY) LEGEND M = Clamp Tr = Consent thermostat...
Page 16
WIRING LC 40 / 56 BASE LEGEND M = Clamp C = Condensator b = Blue m = Brown n = Black gv = Yellow- green Mv1 = Motor fan 1 Mv2 = Motor fan 2 Fig. 10 Connections to be made..... WIRING LC 40 / 56 WITH CONSENT THERMOSTAT...
Page 17
WIRING LC 40 / 56 WITH AMBIANCE THERMOSTAT winter mode To take off the bridge between 0 and 4 Connections to be made..... WIRING LC 40 / 56 WITH AMBIANCE THERMOSTAT, SUMMER MODE (VENTILATION ONLY) LEGEND M = Clamp To take off the Tr = Consent thermostat bridge between C = Condensator...
10.0 STARTING Here are the possible faults with the list of possible causes. In italics are briefly indicated repair or restore operations, which are the responsibility of skilled 10.1 INSPECTIONS technical personnel. Before starting operation, make sure that the rules and regulations on the installation of these devices, 11.3 FANS DO NOT WORK especially with respect to the correct sizing of the...
WARNING! To find additional information about components, please contact: A2B Accorroni E.G. LTD - Phone 071-723991 13.4 ROUTINE MAINTENANCE It is recommended to perform the beginning of each operating season the following steps: A) Simply clean the outside with a damp cloth;...
Page 20
Osimo, September 2010 A2B Accorroni E.G. Ltd. The Legal Representative Altamura Lorenza A2B Accorroni E.G. S.r.l. - 60027 OSIMO (AN) – Via dʼAncona, 37 Tel. 071 723991 r.a. – Fax 071 7133153 – e-mail a2b@a-2-b.it Part. IVA e C.F. 02345650424...
Page 22
A2B Accorroni E.G. s.r.l. Via d’Ancona, 37 - 60027 Osimo (An) - Tel. 071.723991 r.a. - Fax 071.7133153 web site: www.accorroni.it - e-mail: a2b@accorroni.it...