Gas-fired convective air heaters
GHIBLI 4-5-6 ELITE
Cod. 25619502IT - Rev. 0 - 20/03/2013

Advertisement

Table of Contents
loading

Summary of Contents for Accorroni GHIBLI 4-5-6 ELITE

  • Page 1 Gas-fired convective air heaters GHIBLI 4-5-6 ELITE Cod. 25619502IT - Rev. 0 - 20/03/2013...
  • Page 3: Table Of Contents

    A2B ACCORRONI E.G. S.r.l. in any way with regard to others. 6 - A2B ACCORRONI E.G. S.r.l. is responsible for ensuring that its product conforms to the laws, directives andconstruction standards in force at the time the product is sold. Knowledge and compliance with legal regulations and standards regarding plant design, installation, operation and maintenance are the exclusive responsibility of the designer, installer and user.
  • Page 4 CONTROL AND SAFETY DEVICES .................. 12 Gas controller ........................12 Gas unit ..........................12 Fan thermostat ........................12 Safety thermostat ........................12 SECTION 2 - TECHNICAL INFORMATION FOR THE INSTALLER PRECAUTIONS ........................13 Gas safety regulations ......................13 Related documents ....................... 13 Transport and handling ......................
  • Page 5 FIGURE SUMMARY Fig. no. page 1 Dimensions ..........................6 2 Wiring Diagram ..............- Ghibli Model 4 ......7 3 Wiring Diagram ..............- Ghibli Model 5 ......7 4 Wiring Diagram ..............- Ghibli Model 6 ......8 5 Exploded View ..............- Ghibli Model 4 ......9 6 Exploded View ..............
  • Page 6: Principal Characteristics

    SECTION 1 - GENERAL INFORMATION EN 60335-1 and EEC directive 2004/108 1. PRINCIPAL CHARACTERISTICS ("Electromagnetic compatibility") through the 1.1 APPLIANCE CLASSIFICATION standards EN 50081-1 and 50082-1. These appliance are defined as “Independent gas-fired convection heaters incorporating a fan to assist transportation of combustion air and flue gases”.
  • Page 7: Construction Characteristics

    Air heater operation is controlled by the built-in 1.6 ACCESSORIES SUPPLIED ON REQUEST room thermostat and by a digital timer that may In addition to the material described above, the be supplied on request. following accessories can also be supplied on 1.4 CONSTRUCTION CHARACTERISTICS request: The casing is built with ivory-coloured, epoxy-...
  • Page 8: Dimensions

    1.8 DIMENSIONI E INGOMBRI Fig. 1 Aspir./Scar. Ghibli 4 Ø 65 G 3/8" Ghibli 5 - 6 Ø 65 G 3/8" page 6...
  • Page 9: Wiring Diagram

    1.9 WIRING DIAGRAM - Ghibli Model 4 = External auxiliaries supply = Control equipment = Ignition electrode = Flame detection electrode = Gas solenoid valve = RFI filter = On-Off switch M1-2-3 = Connection terminal boards = Flue gas exhaust motor = Fan motor = Bridge for auxiliaries (i.e.: timer) = Reset button...
  • Page 10: Technical Data Table

    1.9 WIRING DIAGRAM - Ghibli Model 6 = External auxiliaries supply = Control equipment = Fan speed switch = Ignition electrode = Flame detection electrode = Gas solenoid valve = RFI filter = On-Off switch M1-2-3 = Connection terminal boards = Flue gas exhaust motor common = Fan motor...
  • Page 11: Exploded View

    page 9...
  • Page 12 page 10...
  • Page 13 Legend of components Ghibli 4 (see fig. 5) Legend of components Ghibli 5 and 6 (see fig.6) Pos Codice ............Description Pos Code description 45610001 ........Casing Ghibli 5/6 Elite 45660001 ........Casing Ghibli 5/6 Elite 45810002 ........Screw for casing fixing 45810002 ........
  • Page 14: Control And Safety Devices

    2.2 GAS VALVE 2. CONTROL AND SAFETY DEVICES The gas valve includes two, direct operation 2.1 GAS CONTROLLER solenoid valves with class B closing devices This device is housed in a heat-resistant and (maximum pressure 50 mbar) and a pressure shockproof plastic enclosure and is mounted on regulator.
  • Page 15: Section 2 - Technical Information For The Installer

    SECTION 2 TECHNICAL INFORMATION FOR THE INSTALLER 3. PRECAUTIONS The type of gas for which the heater has been designed and the supply pressure are found 3.1 GAS SAFETY REGULATIONS on the exterior of the packing and on a special The law requires all gas appliances to be label located on the inside of the appliance.
  • Page 16: Air Intake And Flue Exhaust Ducts

    sensitive, the passage hole must be POSIZIONAMENTO protected with insulation that insulates the wall or the covering. 4.2.1 Type definition As already mentioned in point 1.1, the Ghibli air heater can be installed with different configurations min. 20 cm of the air intake and combustion product exhaust duct(s) and these different solutions constitute the definition of "type"...
  • Page 17: Outside Positioning Of The Flue Gas Exhaust Terminal

    TYPE C INSTALLATION TOP VIEW Using the doubling device (supplied on request), it is possible to create different configurations of the air intake and flue gas exhaust ducts, within specified limits. The external terminals are not required to be Fig. 13 adjacent to each other.
  • Page 18: Intake/Exhaust Duct

    INTAKE / EXHAUST DUCT LOCATION OF THE DOUBLING DEVICE (Type C - standard supply) IN THE WALL (top view) Air intake and flue Attachment gas exhaust duct screw Terminal WARNING! (Side flush with wall) Wall thickness Fig. 15 Fig. 17 a) precisely measure the thickness of the wall.
  • Page 19 bendable type in stainless steel. Connect the 4.4.4 Appliance wall mounting ducts to the doubling device using metal clamps a) Appliance with standard supply - and tighten them to ensure a good seal on the Installation Type C fitting. With the doubling device connected in Lift the appliance and, putting the intake/exhaust this manner, place it in the housing and block it duct at the beginning of the hole, push it toward...
  • Page 20: Start-Up

    4.4.7 Using a timer (the kit is supplied on POWER SUPPLY CABLE CONNECTION request) To operate the air heater automatically at predetermined hours, it is possible to install a Blue digital timer on the appliance, even after the appliance has already been installed. The timer Brown is supplied on request as an assembly kit.
  • Page 21: Ignition

    5.2 IGNITION been purged and the ignition is regular. 5.2.1 Ignition procedure The exchanger heating phase begins after the burner has been ignited. The exchanger reaches (Refer to fig. 21 when reading the following the rated operating temperature after about three section ) minutes and at that point a thermostat starts the a) Place switch (A) in the on position "I"...
  • Page 22: Gas Type Change

    6. GAS TYPE CHANGE f) unscrew the pressure regulator protection plug located on the gas unit. With care, fully tighten WARNING! The operations described below the plastic screw of the pressure regulator. must be carried out by skilled technical Insert the screw block with pin instead of the personnel.
  • Page 23: Operating Defects

    STANDARD GAS CHANGE Plastic pressure Gas unit regulator screw Protection plug Screw block with pin for group 3 gas Gas injector Fig. 23 f) start the air heater according to what is 7.2 POSSIBLE DEFECTS indicated in point 5.2 The following is a list of possible defects along g) insert the water column pressure gauge tube with their probable causes.
  • Page 24 - Restore the connection or replace the accordance with the positions indicated in electrode including the cable. Do not make figure 28. joints to avoid reducing the cable insulation d) The flue gas exhaust fan motor is malfunctioning level. or does not operate correctly because the intake/exhaust duct is obstructed.
  • Page 25: Replacing Parts

    8. REPLACING PARTS GAS UNIT COIL REPLACEMENT Since specific technical skills are required to replace the parts listed below, it is Valve rectifier Gas unit recommended to advise the user to always bridge contact skilled technical personnel. For safety and quality reasons, it is recommended to use original spare parts when replacing components.
  • Page 26: Electrodes

    SAFETY THERMOSTAT REPLACEMENT FLUE EXHAUST REPLACEMENT Exchanger Front shield Gasket Thermostat (printed side) Fastening Attachment screw plate Burner housing Motor/fan Fig. 29 Fig. 27 previous operations. Make sure to insert the side position. Attach the plate using the 6 screws that of the thermostat with the printed data facing the were previously removed.
  • Page 27: Periodic Maintenance Operations

    9. PERIODIC MAINTENANCE FAN REPLACEMENT (Ghibli 5-6) OPERATIONS 9.1 USER INFORMATION Appliance rear panel It is recommended to advise the user to carry out Thermostat the operations indicated in point 11.1 of this manual at least once every two months. 9.2 YEARLY INSPECTION 9.2.1 Control and safety devices WARNING! Specific technical skills are...
  • Page 28: Section 3 - User Operating And Maintenance Instructions

    SECTION 3 USER OPERATING AND MAINTENANCE INSTRUCTIONS of the start-up phase, indicated when the 10. START-UP green led (E) turns on. 10.1 FIRST FIRING AND TESTING c) Check that the red led (F) is turned off. If it is WARNING! The first firing of the appliance on, this means that the burner control and the commissioning tests must be equipment is in the "lockout"...
  • Page 29: Appliance Maintenance

    11. APPLIANCE MAINTENANCE b) clean the external parts of the air heater simply by using a damp cloth and use a brush 11.1 ROUTINE MAINTENANCE TO BE to remove any dust deposits on the air intake PERFORMED BY THE USER grille It is recommended that the following operations c) make sure that the operation of the appliance...
  • Page 30 NOTE page 28...
  • Page 32 A2B ACCORRONI E.G. S.r.l. - Via d’Ancona, 37 - 60027 Osimo (An) Tel. 071.723991 - Fax 071.7133153 - Web Site: www.accorroni.it - E-mail: a2b@accorroni.it...