12. DATA MENU

The following are brief descriptions of features available under the DATA MENU key:
DISPLAY
RATE
DATA
Prn
bEGn
ALrn
on
diSP
on
FAn
0000
*SHFT
1oFF
*SHFT
2oFF
*bin
oFF
FCAL
0
rATE
on
* = GRANULAR APPLICATION ONLY
FEATURE and DESCRIPTION
CONSOLE DATA PRINTOUT
Sends data through serial port to attached optional printer to print field begin
and field end pages.
AUDIBLE ALARMS ON/OFF
Turns audible alarms ON or OFF for the following:
1)
Volume/Area Rate Alarm
2)
Volume/Minute Rate Fault
3)
Low Tank Fault
DISPLAY SMOOTHING ON/OFF
Turns display smoothing ON or OFF. Selecting display smoothing ON
means the RATE window displays target rate when actual rate is within a
percentage of target rate. The third digit of VALVE CAL determines this
percentage.
FAN RPM
Displays fan RPM in DATA window
LEFT SHAFT FAULT ON/OFF
Turns left shaft fault detector ON or OFF. When fault detector is selected
ON; alarm sounds and RATE display flashes "SHA1" if left shaft should be
rotating, but is not.
RIGHT SHAFT FAULT ON/OFF
Turns right shaft fault detector ON or OFF. When fault detector is selected
ON; alarm sounds and RATE display flashes "SHA2" if right shaft should be
rotating, but is not.
BIN LEVEL FAULT ON/OFF
Turns bin level fault detector ON or OFF. When fault detector is selected ON;
alarm sounds and RATE display flashes "bin" if granular level drops below the
bin level sensor.
FAN CALIBRATION
Displays and allows entering on fan calibration number.
RATE CHANGE ALARM ON/OFF
Turns rate change alarm ON or OFF. When rate change alarm is selected
ON; alarm sounds 4 long beeps when the rate 1 calibration number is
changed via the serial port using a valid change request data string.