6.0 Maxxus Power Requirements
Sundance hot tubs are designed to provide optimum performance and
flexibility of use when connected to their maximum electrical service.
However, they are shipped factory configured for their most common
preferred electrical connection as follows:
•
uS/Canada 60Hz Model:
•
Export 50Hz Model:
If you prefer, your Sundance dealer perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see Table below).
Electrical Service Options for Maxxus Models
US/Canada 60Hz Model
Voltage
Max. Current Draw
Number of Wires
Circuit Breaker (2-Pole)
**
In this configuration, the heater will not operate while any two
jets pumps are running.
***
In this configuration the heater will operate while any two jets
pumps and the blower are running but will not operate when
all three jets pumps are running.
Export 50Hz Model
Voltage
Max. Current Draw
Number of Wires
Circuit Breaker (2-Pole)
**
In this configuration, the heater will not operate while any two
jets pumps are running.
***
In this configuration the heater will operate while any two jets
pumps and the blower are running but will not operate when
all three jets pumps are running.
240VAC/60A
230VAC/45A
240VAC
38A
3
**
50A
230VAC
34A
3
**
45A
240VAC
48A
3
***
60A
230VAC
42A
3
***
50A