Download Print this page

STIEBEL ELTRON SHW 200 S Instructions For Installation And Use Manual page 12

Unvented pressurized floor-standing water heater

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
1. Operating instructions
1.1 Unit description
The SHW 200 - 400 S floor-standing water
heater can provide hot water to suit
requirements up to about 82 °C and supply
one or more draw-off points. The water is
heated electrically.
• Stepless temperature adjustment possible
from about 35 °C to about 82 °C
If required, the hot water temperature
limitation set at the works (60 °C) can be
altered by the qualified installer at the
G
electrical heating element
• The water content is heated to the preset
temperature in accordance with the
operating mode.
Single-circuit operation:
Automatic reheating takes place as a
function of the electricity supply.
Dual-circuit operation:
In this operating mode the appliances
provide basic heating, which automatically
heats up the water content during off-peak
periods.
Rapid heating can be switched on if
required by pressing the button (3). Once
the preset temperature has been reached,
the rapid heating mode will be switched
off, and not switched on again.
• The time required for heating up depends
on the cylinder content, the temperature
of the cold water, and the heating capacity.
B
See the diagram
for the heating-up
time at a setting of 60 °C (E) and a cold
water temperature of 10 °C.
1.2 The main points in brief
Temperature selector button (1)
Thermometer (2)
Button for switchable rapid heating mode
(3)
Anode wear display (4)
Operation
Temperature selector button
= Cold (see also note on „Freezing
risk")
I = approx. 40 °C
E = approx. 60 °C (recommended
energy saving setting, low
limescale formation)
III = approx. 82 °C (maximum settable
temperature).
The temperatures may deviate from the
reference values given due to the
particular features of the individual
system.
12
for the user and qualified installer
1.3 Safety instruction
• A hot water temperature of more
than 60 °C may occur at the draw-
off fitting.
• If it is intended that children or persons
with restricted physical, sensory, or
mental capacity should operate the
A
(1).
appliance, it must be ensured that this is
only done after appropriate instruction has
been provided by the person responsible
for their safety. Children should be
supervised to ensure that they do not play
.
with the device.
Risk of scalding!
1.4 Important instruction
• Arrange for the floor-standing water heater
and the safety group to be checked
regularly by a qualified installer.
• The appliances are under water mains
pressure. During heating, expansion water
will drip out of the safety valve. If water
continues to drip after the heating phase
has ended, please inform your qualified
installer.
• The steel cylinder is fitted on the inside
with a special enamel coating to protect it
against corrosion, and also has a protective
anode with a wear display (signal anode).
Once the signal anode has worn away,
moisture will pass to the display element
(4) and cause it to change colour.
If the display element (4) turns red,
please inform your qualified installer
so that he can check the signal anode and
replace it if necessary.
1.8 Technical data
Type
Contents
Weight, empty
Max. flow volume
Permissible operational flow rate
Test mark
Electrical connection
Dimensions
C
(Hole diameter) Ø e mm
Table 1
Risk of freezing
At the temperature selection setting
cold), and under voltage supply, the appliance
is protected against freezing, but not the cold
water feed pipe or the water mains pipe.
1.5 Trouble-shooting
See „3. Fault elimination - User"
1.6 Care and maintenance
• At high temperatures almost all water
• A damp cloth is sufficient for caring for the
1.7 Instructions for
installation and use
(the data on the unit rating plate are applicable)
SHW 200 S
l 200
kg
65
l/min
30
Ø a mm
630
b mm
730
c mm
340
430
h mm 1570
k mm 1035
l mm
350
m mm
60
n mm
80
Maintenance work, such as checking
the electrical safety, may only be
carried out by a qualified installer.
precipitates limescale. This forms deposits
in the appliance and affects its function and
service life. The heating elements must
accordingly have the limescale removed
from time to time.
The qualified installer, who is familiar with
the quality of the local water, will advise
you of the time for the next maintenance
inspection.
plastic components. Do not use any
abrasive or scouring cleaning agents.
Keep these instructions in a safe
place, and give them to the next user
in the event of a change of ownership. In
the event of any maintenance or repair
work being required, provide them to the
qualified installer for his reference.
SHW 300 S
SHW 400 S
300
400
77
90
38
45
0.6 MPa (6 bar)
See appliance rating plate
See appliance rating plate
700
750
815
865
365
375
490
540
1585
1755
1040
1160
390
410
55
55
75
75
(=

Advertisement

loading

This manual is also suitable for:

Shw 300 sShw 400 s