STIEBEL ELTRON SHZ 30 S Operation And Installation

STIEBEL ELTRON SHZ 30 S Operation And Installation

Wall mounted dhw cylinder

Advertisement

OPERATION AND INSTALLATION
Wall mounted DHW cylinder
» SHZ 30 S (GB)
» SHZ 50 S (GB)
» SHZ 100 S (GB)
» SHZ 150 S (GB)

Advertisement

Table of Contents

Troubleshooting

loading
Need help?

Need help?

Do you have a question about the SHZ 30 S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STIEBEL ELTRON SHZ 30 S

  • Page 1 OPERATION AND INSTALLATION Wall mounted DHW cylinder » SHZ 30 S (GB) » SHZ 50 S (GB) » SHZ 100 S (GB) » SHZ 150 S (GB)
  • Page 2: Table Of Contents

    CONTENTS SPECIAL INFORMATION Specification ������������������������������������������������ 10 16.1 Dimensions and connections ��������������������������������� 10 OPERATION 16.2 Minimum clearances ������������������������������������������� 11 General information �����������������������������������������3 16.3 Controller-limiter combination immersion depths������� 11 Safety instructions ����������������������������������������������� 3 16.4 Wiring diagrams and terminals ������������������������������ 11 Other symbols in this documentation ����������������������� 4 16.5 Hydraulic diagram ����������������������������������������������...
  • Page 3: Special Information

    SPECIAL INFORMATION | OPERATION General information SPECIAL INFORMATION OPERATION - The appliance may be used by children aged 8 General information and older and persons with reduced physical, sensory or mental capabilities or a lack of ex- The chapters “Special Information” and “Operation” are intended for both the user and qualified contractors.
  • Page 4: Other Symbols In This Documentation

    OPERATION Safety Other symbols in this documentation Note The appliance is under pressure. During the heat-up pro- Note cess, expansion water will drip from the outlet side of the General information is identified by the symbol shown safety valve and / or of the T&P valve. If water continues on the left.
  • Page 5: Settings

    If you cannot remedy the fault, notify your qualified contractor. maximum draw-off volume is reached. To facilitate and speed up your enquiry, please provide the serial number from the type plate (000000-0000-00000): SHZ 30 S (GB) SHZ 50 S (GB) Nr.: 000000-0000-000000 SHZ 100 S (GB) l...
  • Page 6: Installation

    INSTALLATION Safety INSTALLATION Preparations Installation site The appliance is exclusively designed for installation on a solid Safety wall. Ensure the wall offers adequate load bearing capacity. Only a qualified contractor should carry out installation, commis- Always install the appliance vertically in a room free from the risk sioning, maintenance and repair of the appliance.
  • Page 7: Installation

    INSTALLATION Installation 10. Installation See chapter "Specification / Hydraulic diagram" for the general arrangement in schematic form. You can fit the safety assembly in various positions to suit the space available but it must be placed 10.1 Appliance installation in the same order as shown. The safety assembly provided in the pack is fitted to the cold water supply with the exception of the T&P valve which is fitted at the top of the DHW cylinder.
  • Page 8: Completing The Installation

    INSTALLATION Commissioning 11.1.1 Appliance handover f Explain to users how the appliance and the safety assembly work and familiarise them with their operation. f Make the user aware of potential dangers, especially the risk of scalding. f Hand over these instructions. 11.2 Recommissioning See chapter "Commissioning".
  • Page 9: Troubleshooting

    INSTALLATION Troubleshooting 14. Troubleshooting 15.2 Draining the appliance WARNING Burns Note Hot water may escape during the draining process. The high limit safety cut-out can respond at temperatures below –15 °C. The appliance may be subjected to these If the cylinder needs to be drained for maintenance or to protect temperatures during storage or transport.
  • Page 10: Specification

    INSTALLATION Specification 16. Specification 16.1 Dimensions and connections SERVICE ANODE °C SHZ 30 S (GB) SHZ 50 S (GB) SHZ 100 S (GB) SHZ 150 S (GB) Appliance Height 1126 1521 Appliance Width Appliance Depth b02 Cable entry I PG 21...
  • Page 11: Minimum Clearances

    16.3 Controller-limiter combination immersion depths N L1 L2 L3 5 6 1 Limiter sensor 2 Controller sensor 1 Terminal for output changeover SHZ 30 S SHZ 50 S SHZ 100 S SHZ 150 S 2 Plug-in distributor for N conductor (GB)
  • Page 12 INSTALLATION Specification Dual circuit operation with dual meter capture Single circuit operation 1/3 kW 1/N/PE ~ 230 V 1 kW 1/N/PE ~ 230 V 7 8 9 7 8 9 2/4 kW 1/N/PE ~ 230 V 2 kW 1/N/PE ~ 230 V 7 8 9 7 8 9 N L1 L2 L3 5 6 3 kW...
  • Page 13: Hydraulic Diagram

    INSTALLATION Specification 16.5 Hydraulic diagram 16.6 Heat-up diagrams The heat-up time depends on the cylinder capacity, cold water < 500 inlet temperature and heating output. Diagrams refer to 15 °C cold water inlet temperature: Temperature setting 50 °C 3 2 1 1 Discharge below fixed grate 2 Cold water supply 3 Shut-off valve...
  • Page 14 Specification 16.8 Details on energy consumption Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP). SHZ 30 S (GB) SHZ 50 S (GB) SHZ 100 S (GB) SHZ 150 S (GB)
  • Page 15 GUARANTEE | ENVIRONMENT AND RECYCLING Guarantee The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products a guarantee can only be issued by those subsidiaries. Such guarantee is only grant- ed if the subsidiary has issued its own terms of guarantee.
  • Page 16   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.

This manual is also suitable for:

Shz 30 s gbShz 50 sShz 50 s gbShz 100 sShz 100 s gbShz 150 s ... Show all

Table of Contents