Summary of Contents for Oldham OX 2000

  • Page 2 GAS AND FLAME DETECTION STACK GAS AND DUST MONITORING We thank you for choosing an OLDHAM SA instrument. We have taken every step to ensure that this equipment continues to give you complete satisfaction. Please read the instruction manual carefully before using the instrument.
  • Page 3 OLDHAM SA, even if involved in the sale of the products of OLDHAM SA. * OLDHAM SA shall not be liable for any direct or indirect damage, or any direct or indirect legally awarded damages resulting from the sale and use of any of its products, UNLESS THOSE PRODUCTS WERE SPECIFIED AND CHOSEN BY OLDHAM SA FOR THE USE MADE OF THEM.
  • Page 4 General view Protective filter for module clip Protective cover for module Back lighted liquid cristal display Colour ring mentionning type of module Visual indicator Buzzer (audible alarm) Mini and maxi detected at the last utilisation Current batteries voltage Tactile keys...
  • Page 5 Inside view Rep 1 Rep 1 Rep 2...
  • Page 6 TX2000 (+) "HBCO"Version Te shape sampling device (plastical) Interchangeable tip (pasteboard) COHB ELL CAP NOZZLE SPECIFIC TO TX 2000 (+) "CO"...
  • Page 7: Table Of Contents

    Reinitialization of the dry batteries "controller"............11 MEASUREMENT SENSOR (toxic or oxygen) ..............11 3.1. Presentation ........................11 3.2. Fitting or replacement....................11 CARRIAGE OF THE TX2000(+) / OX 2000(+)..............12 USE ............................12 OPERATING THE INSTRUMENT .................12 DATA GIVEN BY THE DISPLAY ...................13 SWITCHING ON.........................13 SWITCHING OFF.......................14 ILLUMINATION.........................15...
  • Page 8: Presentation

    See figure 1 at the beginning of this manual he TX/OX2000(+) is a stand-alone, “ pocket ” oxygenometer or toximeter intended for the (continuous) detection of toxic or oxygen gases or vapours. The TX/OX2000(+) is equipped with a plug-in sensor which can be accessed after unscrewing the sensor cap on the top of the instrument.
  • Page 9: Fitting Or Replacement Of Dry Batteries

    See figure 2 at the beginning of this manual Ø - Remove the rear protective caps of the TX/OX 2000 after having the four screws undone (rep 1) - Fit the dry batteries into the compartment tought for this purpose (rep 2).
  • Page 10: Reinitialization Of The Dry Batteries "Controller

    Reinitialization of the dry batteries "controller" 2.2. • to do at every replacement of dry batteries • TX/OX 2000+ switch off Press 30 seconds on those 2 keys ENTER - Release the keys when bat appears - bat is still displaying during 5 seconds End of the réinitialization after 5 seconds...
  • Page 11: Carriage Of The Tx2000(+) / Ox 2000(+)

    IMPORTANT : This work is reserved for authorized and qualified personnel since it could possibly jeopardize the safety of detection. • Clip (fig 1.rep2) The user can get on with his work while leaving the instrument to monitor the surrounding atmosphere: the TX/OX2000(+) is attached to his clothing using the clip provided for the purpose Attention : in order to be able to take readings correctly, the sensor should never...
  • Page 12: Data Given By The Display

    The liquid Crystal display allows messages to be read clearly: 3 digits 1/2 for displaying the measurement • • Equipped with back light by light-emitting diodes. 4 pictograms supplementing the audible and visual alarms relating to the • exceeding of thresholds, battery faults, maintenance mode. The TX/OX2000(+) is switched on by pressing momentarily on the following key ENTER A regular audible “...
  • Page 13: Switching Off

    "Average on 8 hours" (TWA) Alarm threshold on 8 hours Average on 15 mn (STEL) Alarm threshold on 15 mn Display of test period (stabilisation) (alternatively “tst” and remaining time). Display of measurement or (depends on version), after stabilisation time. Note : The instrument is initialised to detect only one type of gas (toxic or oxygen).
  • Page 14: Illumination

    In order to read the measurement in dark locations it is possible to illuminate the display by momentarily pressing the following key : 2 red light-emitting diodes placed on either side of the display provide this illumination for 10 seconds (as standard). By pressing momentarily and successively on the following key In first press on key, display is back-lighed then : The lowest measurement detected since the instrument was switched on...
  • Page 15: Manual Acknowlegment Of " Mini " Et " Maxi

    Averaged alarm on 8 hours : TWA "TWA" current value permanently calculated _ _ _ _ _ _ _ _ _ _ _ Test of dry batteries Segments indicating dry batteries or batteries operating (the number of segments depends on remaining of autonomy) I I I I _ _ _ _ _ _ _ _ __ _...
  • Page 16: The Alarms

    • : The STEL and TWA thresholds are programmed by OLDHAM at the reinitialization of the device and cannot be modified by the user. The thresholds are programmed by default following the certificated values. It is identified by the pictogram * Oxygenometer version : •...
  • Page 17 pulsed Table of “ ” audible and visual alarms DISPLAY CAUSE REMEDY Instantaneous or averaged Alarm can be cleared GAS (special version) threshold exceeded manually XPPM or % O Instantaneous or averaged Alarm can be cleared Alarm pictogram threshold exceeded manually Audible and visual The battery is beginning...
  • Page 18 DISPLAY CAUSE REMEDY Dry batteries are worn : - Switch off the instrument the instrument is no - Alarm cannot be cleared pictogramme longer usable. - Replace dry batteries pack Measurement range - Alarm can be cleared exceeded manually Zero fault : sensor zero too much shifted to low Calibrate (cyclic)
  • Page 19: Clearing The Alarms

    * Clearing the instantaneous GAS, STEL and TWA alarms: by pressing momentarily on the following button Clearing the alarm involves cancelling the “ pulsed ” audible signal and turning off the alarm indicator on condition that the user has left the danger area. NB : if the audible alarm is cleared while a threshold is still exceeded : the indicator will continue to flash and the corresponding pictogram will remain "steady".
  • Page 20: Maintenance And Servicing

    Important Being a safety instrument , it is necessary to calibrate the TX2000(+) or OX 2000(+) at least once a year following use This work is reserved for authorized and qualified personnel since it could possibly jeopardize the safety of detection.
  • Page 21: Programming

    The "programming" menu allows manual programming of the adjustable alarm threshold: threshold 1 for toxic version [TX2000(+)], or up or down thresholds in oxygen version [OX 2000(+)]. Programming example in toximeter version : Display the "PROGRAMMING menu Enter the programming menu...
  • Page 22: Calibration

    “ Calibration ” menu consists of - setting the zero in clean air and the sensitivity with calibration gas in TX2000(+) version (toxic gases). - Adjust oxygen sensitivity in OX 2000(+) version. Adjusting the zero in clean air (only for toximeter version) 3.2.
  • Page 23: Adjusting The Sensitivity

    To adjust value “ zero ” if necessary (in reality, 1 pression on "+" or "-" put the value to "0") to enter the zero adjustment ENTER Adjusting the sensitivity [TX2000(+) and OX 2000(+)] : 3.3. • Position the gas inlet pipe level with the sensor •...
  • Page 24 To adjust calibration gas correct value To enter the adjustment of sensitivity ENTER Display confirmation of sensibility requested Acceptance of request for confirmation ENTER Display the confirmation: NO Display of "YES or NO" for confirmation (with each depression of the button) Display the confirmation: YES Enter the chosen confirmation ENTER...
  • Page 25: Sensor Replacement

    Necessary when : - Calibration not to be done (low sensibility) so sensor is worn out (DEF4). - Wrong type of sensor connection (DEF128), for example (see table of faults). IMPORTANT : This work is reserved for authorized and qualified personnel since it could possibly jeopardize the safety of detection.
  • Page 26: Spare Parts List

    6.111.204 OX/TX2000 housing 6.121.549 WARNING : Only use guaranteed original OLDHAM spare parts ; the safety of the equipment could be jeopardized if you use any other parts. The device is intrinsically safe, substitution of components may impair intrinsic safety.
  • Page 27: List Of The Differents Sensors

    Range Part Number Color Ring 500 ppm 6 313 615 GREEN 300 ppm 6 313 615 GREEN 2000 ppm 6 313 672 GREEN ou HBCO BLUE 100 ppm 6 313 616 (ral 5015) 100 ppm 6 313 617 30 ppm 6 313 618 ROUGE CLAIR 100 ppm...
  • Page 28: Technical Data

    Manufacturer OLDHAM ARRAS (France) Function Gas detector Type TX2000(+) or OX 2000(+) Gas detected toxic or oxygen gas or vapours Measurement continuous Mode Clear display on content (% or ppm) Sensor can be unplugged for maintenance Display liquid crystal Screen...
  • Page 29 Audible alarm : buzzer, 80db at 30 cm Power supply : • 1 lithium dry batteries pack : autonomy maxi : 7000 hours • 3 LR01 dry batteries : averaged autonomy : 1500 hours Miscellaneous : • Keypad control with 3 buttons •...
  • Page 31: Sensors

    Sensors can be unplugged for replacement Data chart of different sensors Partial pressure O2 (1) Standard 500 ppm CO range 30 % 100 ppm 2000 ppm 2000 ppm 30 ppm 30 ppm 100 ppm 30 ppm 100 ppm 1000 ppm 1 ppm 10 ppm 20 à...
  • Page 32: Interferents

    Interferents : 2.1. Interferences Reading S 30 ppm HCN 30 ppm TX2000(+) 100 ppm CO 500 ppm NO 49 ppm 11 ppm 30 ppm 100 ppm S 30 ppm HCN 30 ppm TX2000(+) 100 ppm CO 2000 ppm NO 49 ppm 11 ppm 30 ppm 100 ppm...
  • Page 33: Hbco" Version

    10 ppm S 25 ppm TX2000(+) NO 50 ppm HCl 30.0 100 ppm 1000 ppm CO 100 ppm Ethanol 100 ppm 10 ppm -1.5 30 ppm S 10 ppm TX2000(+) NO 50 ppm HCN 30.0 100 ppm 1000 ppm CO 100 ppm Ethanol 100 ppm "...