Supermicro X11DAi-N User Manual page 47

Hide thumbs Also See for X11DAi-N:
Table of Contents

Advertisement

Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Overheat(OH)/Fan Fail/PWR Fail/UID LED
Connect an LED cable to pins 7 and 8 of the Front Control Panel(JF1) to use UID/Overheat/
Fan Failure/Power Fail LED connections. The LED on pin 8 provides warnings of overheat,
power failure or fan failure. Refer to the tables below for more information.
Information LED (UID/OH/PWR Fail/Fan Fail LED)
Pin Definitions (Pin 7 & Pin 8 of JF1)
Pin# Definition
7
Blue UID LED
8
OH/Fan Fail/PWR Fail LED
Status
Solid red
Blinking red (1Hz)
Blinking red (0.25Hz)
Solid blue
Blinking blue (300 msec)
X11DAi-N
REV:1.01
BAR CODE
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Supply Fail
State
Off
On
Flashing
Information LED (UID/OH/PWR Fail/Fan Fail LED)
Pin Definitions (Pin 7 & Pin 8 of JF1)
Description
An overheat condition has occurred. (This may be caused by cable congestion).
Fan failure: check for an inoperative fan.
Power failure: check for a non-operational power supply
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
MAC CODE
47
Chapter 2: Installation
Information LED (UID/OH/PWR Fail/Fan Fail LED)
State Definitions (Pin 7 & Pin 8 of JF1)
Definition
Normal
Overheat
Fan Fail
1. Power Fail LED
2. OH/Fan Fail/Power Fail LED
3. UID LED
1
2
PWR
Power Button
Ground
Ground
Reset
Reset Button
3.3V
3
UID LED
3.3V Stby
3.3V Stby
3.3V Stby
3.3V
NMI
19
20
1
Power Fail LED
2
OH/PWR Fail/Fan Fail LED
NIC2 Active LED
NIC1 Active LED
HDD LED
PWR LED
Ground

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents