Process Connections With Flush-Mounted, Metal Process Isolating Diaphragm - Endress+Hauser Cerabar PMC11 Technical Information

Pressure transducer with ceramic and metal sensors
Hide thumbs Also See for Cerabar PMC11:
Table of Contents

Advertisement

Process connections with
flush-mounted, metal
process isolating diaphragm
Device
Designation
PMP11
Thread ISO 228 G ½" A
PMP21
DIN3852, shape E
1)
Product Configurator, order code for "Process connection"
1)
Device
Designation
PMP11
Thread ISO 228 G ½" A
PMP21
O-ring seal, flush-mounted
1)
Suitable for weld-in adapter 52002643 and 52010172
2)
Product Configurator, order code for "Process connection"
38
Thread ISO 228 G
1
1
FKM form seal, pre-mounted
Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)
Material
Nominal value
to 100 bar (1 500 psi)
Weight
kg (lbs)
316L
0.140 (0.31)
1
2
1
FKM form seal, pre-mounted
2
FKM O-ring, pre-mounted
Engineering unit mm (in). Diameter of process isolating diaphragm: 17.2 mm (0.68 in)
Cerabar PMC11, PMC21, PMP11, PMP21
SW/AF
G ½" A
ø18 (0.71)
ø26 (1.02)
ø31.5 (1.24)
Nominal value
400 bar (6 000 psi)
Height C
SW/
Weight
AF
kg (lbs)
41 (1.61)
32
0.120 (0.26)
32
G ½" A
ø18 (0.71)
ø26 (1.02)
ø31.5 (1.24)
Material
Weight
kg (lbs)
316L
0.150 (0.33)
A0021971
1)
Option
Height C
SW/
AF
35 (1.38)
32
WJJ
A0022802
2)
Option
WUJ
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cerabar pmc21Cerabar pmp11Cerabar pmp21