COMPRESSOR MOTOR DATA
COMPRESSOR
MODEL*
VOLT
06EA(2/5)50100
575
(2/5)50600
400/460
(2/5)50300
208/230
(2/5)50300
460
06EA(2/5)65100
575
(2/5)65600
400/460
(2/5)65300
208/230
(2/5)65300
460
06EA(2/5)75100
575
(2/5)75600
400/460
(2/5)75300
208/230
(2/5)75300
460
06EA(2/5)99100
575
(2/5)99600
400/460
(2/5)99300
208/230
(2/5)99300
460
*The last two digits of the compressors model number may vary. See page 4. The fifth digit in ( ) of the compressor model number represents models with or
without oil. 0, 1, 2 signifies older models with oil; 3, 4, 5 signifies newer models without oil. See page 4.
COMPRESSOR MOTOR DATA
FOR
3 PHASE
COMPRESSOR
60HZ
MODEL*
VOLTAGE
06ER(1/4)50
208/230
06ER(1/4)65
208/230
06ER(1/4)75
208/230
06ER(0/3)99
208/230
06EM(1/4)50
208/230
06EM(1/4)75
208/230
06EM(1/4)99
208/230
06EA(2/5)50
208/230
06EA(2/5)65
208/230
06EA(2/5)75
208/230
06EA(2/5)99
208/230
*The fifth digit in ( ) of the compressor model number represents models with or without oil. 0, 1, 2 signifies older models with oil; 3, 4, 5 signifies newer models
without oil. See page 4.
MAX.
MUST
MAX.
TRIP
MAX.
LRA
AMPS
RLA
HP
kW
45
32.1
120
54
38.6
173
20
25.3
108
77.1
345
54
38.6
173
57
40.7
164
70
50
223
25
33.6
140
100
446
70
50
223
65
46.4
176
84
60
253
30
39.1
168
120
506
84
60
253
94
67.1
276
118
84.3
345
40
54.0
236
168.6
690
118
84.3
345
Table 8 – High Temperature - Across the Line Start
MAX.
MUST
MAX.
TRIP
MAX.
LRA
AMPS
RLA
XL
HP
kW
15
22.0
90
64.3
283
108
77.1
345
20
25.3
20
25.3
108
77.1
345
168
120
506
30
39.1
15
22.0
90
64.3
283
25
33.6
140
100
446
35
47.6
193
137.9
610
20
25.3
108
77.1
345
25
33.6
140
100
446
168
120
506
30
39.1
40
54.0
236
168.6
690
Table 9 – Part Winding
RECOMMENDED
CIRCUIT
LRA PW
BREAKER
(1ST
XL
PART NO.
WINDING)
72
HH83XA461
104
HH83XA424
207
HH83XB625
104
HH83XA424
98
HH83XA469
134
HH83XA426
268
HH83XC509
134
HH83XA426
106
HH83XA430
152
HH83XA478
304
HH83XC539
152
HH83XA478
165
HH83XA551
207
HH83XA550
414
HH83XC537
207
HH83XA550
RECOMMENDED
CIRCUIT
LRA PW
BREAKER
(1ST
PART NO.
WINDING)
170
HH83XE633
207
HH83XE622
207
HH83XE622
304
HH83XE652
170
HH83XE633
268
HH83XE621
366
HH83XE609
207
HH83XE622
268
HH83XE621
304
HH83XE652
414
HH83XE660
28
CIRCUIT BREAKER DATA
MUST
MUST
HOLD
TRIP
AMPS
AMPS
LRA
33
38
124
42
49
175
91
104
350
42
49
175
46
53
164
55
64
210
110
127
420
55
64
210
50
56
188
65
76
274
142
163
507
65
76
274
74
85
236
92
106
295
187
215
636
92
106
295
CIRCUIT BREAKER DATA
1/2 WINDING
LRA
LRA
MUST
MUST
1ST
2ND
HOLD
TRIP
WIND
WIND
AMPS
AMPS
38
44
152
120
46
53
212
171
46
53
212
171
69
80
332
243
38
44
152
120
55
64
255
205
78
90
380
300
46
53
212
171
55
64
255
205
69
80
332
243
100
115
414
345
RECOMM.
RLA
27.1
35.0
74.3
35.0
37.8
45.7
90.7
45.7
41.4
54.3
116.4
54.3
60.7
75.7
153.6
75.7
RECOMM.
RLA
62.8
75.8
75.8
114.2
62.8
91.4
128.6
75.8
91.4
114.2
164.2