12. Disposal

Electronic devices are recyclable waste and must not be placed in household waste. At the end of its
service life, dispose of the product in accordance with applicable regulatory guidelines.
You thus fulfil your statutory obligations and contribute to environmental protection.

13. Technical data

Input voltage/current ......................................... 1 00 - 120 V AC or 220 - 240 V AC, 50/60Hz
Power consumption ..........................................max. 460 W, max. 4.6 A
Charging power ................................................300 W AC, 2x 300 W DC
Charging voltage/current ..................................max. 26.1 V/0.1 - 16 A
DC input voltage ...............................................9 - 32 V/DC, max. 680 W
Discharging power ............................................8 W, (200 W with external discharge device)
Suitable for ....................................................... L i-Po/Li-HV/Li-ion/Li-Fe battery 1-6S
Operating conditions .........................................0 to +40°C, 0 - 90% relative humidity (non-condensing)
Storage conditions ............................................-20 to +60°C, 0 - 90% relative humidity (non-condensing)
Dimensions (L x W x H) ....................................120 x 115 x 75 mm
Weight ..............................................................800 g
(can be adjusted with voltage selector switch)
Ni-Cd/Ni-MH battery 1-16S
Lead battery 1-12S