XYR 6000 Pressure continued ..
 Description
 Name
SENSOR_DEVREV
Device Revision
SENSOR_BUILD
Software Version
MAINTENANCE_ALERT
Maintenance Alert
MAINTENANCE_ALERT.ALERT_DISABLE
Enable or Disable the Alert
MAINTENANCE_ALERT.ALERT_PRIORITY
Priority set for the Alert
OUT_OF_SPEC_ALERT
Out of Specification Alert
OUT_OF_SPEC_ALERT.ALERT_DISABLE
Enable or Disable the Alert
Priority set for the Alert
OUT_OF_SPEC_ALERT.ALERT_PRIORITY
FUNCTION_CHECK_ALERT
Function Check Alert
FUNCTION_CHECK_ALERT.ALERT_DISABLE
Enable or Disable the Alert
FUNCTION_CHECK_ALERT.ALERT_PRIORITY
Priority set for the Alert
FAILURE_STATUS_ALERT
Failure Status Alert
FAILURE_STATUS_ALERT.ALERT_DISABLE
Enable or Disable the Alert
FAILURE_STATUS_ALERT.ALERT_PRIORITY
Priority set for the Alert
POWER_SOURCE
Power source
V_POWER
Power voltage
EUI_64
Field device radio EUI64 unique identifier.
DL_ALIAS_16_BIT
Field device radio short address.
Field device radio IP6 address.
NETWORK_ADDRESS_128_BIT
DEVICE_ROLE_CAPABILITY
Field device radio role capability.
VENDOR_ID
Field device radio vendor ID.
MODEL_ID
Field device radio model ID.
TAG_NAME
Field device tag name.
SERIAL_NUMBER
Field device radio serial number.
POWER_SUPPLY_STATUS
Field device power supply status.
JOIN_COMMAND
Field device radio join command.
RESTART_COUNT
Field device radio restart counter.
Field device radio uptime.
UPTIME
SOFTWARE_REVISION
Field device radio revision.
DROP_OFF_COUNT
Field device radio network drop off counter.
JOIN_ATTEMPT_COUNT
Field device radio network join attempt counter.
RESET_COUNTERS
Field device radio reset counters command.
ROUTING_ASSIGNMENT
Field device radio network routing assignment.
Revision 3
March 2012
Data Type
Data Size Access
Uint16
2 Read Only
Uint16
2 Read Only
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
BinaryAlarmDesc
2 Read/Write Static
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
Uint8
1 Read Only
Float
4 Read Only
OctetString
0 Read Only
Uint16
2 Read Only
OctetString
0 Read Only
Uint16
2 Read Only
VisibleString
16 Read Only
VisibleString
16 Read Only
VisibleString
16 Read/Write Static
VisibleString
16 Read Only
Uint8
1 Read Only
Uint8
1 Read/Write Static
Uint16
2 Read Only
Uint32
4 Read Only
VisibleString
16 Read Only
Uint16
2 Read Only
Uint16
2 Read Only
Boolean
1 Read/Write Static
Uint8
1 Read/Write Static
OneWireless XYR 6000 ISA100.11a Compliant Pressure Transmitter User's Manual
Enum Value
Class
Static
Static
Dynamic
1 ‐ Battery Module
2 ‐ 24V External Power Module
Dynamic
Constant
Static
Static
Constant
128 ‐ Provisioning Device
64 ‐ System Time Source
32 ‐ Security Manager
16 ‐ System Manager
8 ‐ Gateway
4 ‐ Access Point
2 ‐ Routing Device
1 ‐ I/O Device
Constant
Constant
Constant
Dynamic
0 ‐ Line Powered
1 ‐ Battery
2 ‐ Battery
3 ‐ Battery
0 ‐ None
2 ‐ Warm Restart
3 ‐ Restart as Provisioned
Static
Dynamic
Constant
Static
Static
0 ‐ Routing Disabled
1 ‐ Routing Enabled
2 ‐ Not Applicable
Enum Description
Device is powered by internal battery
Device is powered using 24V external 
power
Provisioning Device
System Time Source
Security Manager
System Manager
Gateway
Access Point
Routing Device
I/O Device
Line Powered
High
Battery powered
greater than 75% remaining
Medium
Battery powered
between 25% to 75% remaining
Low
Battery powered
less than 25% remaining
None
Warm Restart
Restart as Provisioned
Routing Disabled
Routing Enabled
Not Applicable