Water - Scotsman Prodigy Plus A Series Service Manual

Modular flake and nugget
Hide thumbs Also See for Prodigy Plus A Series:
Table of Contents

Advertisement

NH0422, NS0422, FS0522, NH0622, NS0622, FS0822, NH0922, NS0922, FS1222, NH1322, NS1322, FS1522
Air, Water or Remote Service Manual

Water

The water supply for ice making must be cold, potable
water. There is a single 3/8" male flare potable water
connection on the back panel. Water cooled models
also have a 3/8" FPT inlet connection for the water
cooled condenser. Chilled water can also be used for
this connection.
Drain
There is one ¾" FPT condensate drain fitting at the
back of the cabinet. Water cooled models also have a
½" FPT discharge drain connection on the back panel.
Tubing
Connect the potable water supply to the potable water
fitting, 3/8" OD copper tubing or the equivalent is
recommended.
Water filtration is recommended. If there is an existing
filter, change the cartridge.
Connect the water cooled water supply to the
condenser inlet.
Note: Do NOT filter water to the water cooled
condenser circuit.
Connect the drain tube to the condensate drain fitting.
Connect the water cooled condenser drain tube to the
condenser outlet.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser.
Follow all local and national codes for tubing, traps
and air gaps.
Water Inlet
Connection
Drain
Connection
Condensate
Drain Tube
Building Drain
Air Cooled or Remote Plumbing
Water Inlet
Connection
Drain
Connection
Condensate
Drain Tube
Water Cooled Plumbing
July 2020
Page 9
Condenser Inlet
Connection
Condenser
Drain Tube