Autoalert And Display Code - Scotsman Prodigy Plus A Series Service Manual

Modular flake and nugget
Hide thumbs Also See for Prodigy Plus A Series:
Table of Contents

Advertisement

NH0422, NS0422, FS0522, NH0622, NS0622, FS0822, NH0922, NS0922, FS1222, NH1322, NS1322, FS1522
Air, Water or Remote Service Manual

AutoAlert and Display Code

The controller uses indicator lights to provide the user
with information on Power, Status, Water or Time to
Clean. These are known as the AutoAlert panel.
Additionally a 7 segment display is under the front
panel. It shows operational status or problem codes.
The Power light is on Green anytime the machine is
supplied with electrical power.
The Status light is on Green when the machine has
been switched to the ice making mode. It will also
blink green if the unit has been equipped with an
optional Smart-Board AND the Smart-Board has
detected potential malfunction.
The Water light will blink Red if the water sensor does
not detect water.
The De-Scale / Sanitize light will glow Yellow when
the time to clean timer has reached its set time since
the last cleaning. It also blinks during the first part of
the cleaning mode
Code Description
. . . . . . . . Freeze Mode
flashes . . Freeze Mode is Pending
. . . . . . . . Bin is Full
. . . . . . . . Clean Cycle
. . . . . . . . Board Locked
. . . . . . . . Test Mode
. . . . . . . . Off
. . . . . . . . Self Test Failed
flashes. . No ice sensed - Retrying
. . . . . . . . . No ice sensed - Shut Down
flashes . Auger motor high load - Retrying
. . . . . . . . Auger motor high load - Shut Down
. . . . . . . . No water in reservoir
. . . . . . . . Refrigeration pressure too high / low
July 2020
Page 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents