Air, Water or Remote Service Manual

For The Installer: Remote Condenser

Locate the condenser as near as possible to the
interior location of the ice machine. Allow it plenty of
space for air and cleaning: keep it a minimum of two
feet away from a wall or other rooftop unit.
Note: The location of the condenser relative to the ice
machine is LIMITED by the specification on the prior
Power Supply from
page.
Ice Machine
Roof penetration. In many cases a roofing contractor
will need to make and seal the hole in the roof for the
line sets. The suggested hole diameter is 2 inches.
Meet all applicable building codes.
Roof Attachment
Install and attach the remote condenser to the roof
of the building, using the methods and practices of
construction that conform to the local building codes,
Remote Condenser
including having a roofing contractor secure the
condenser to the roof
Refrigeration
To Remote Condenser
connections
Brazing required
Refrigeration
Tubing
July 2020
Page 14