Kroll TK30 Instruction Handbook Manual

Hide thumbs Also See for TK30:

Advertisement

Quick Links

INSTRUCTION HANDBOOK
Dehumidifier
Original manual
057614-21 / March 2020

Advertisement

Table of Contents
loading

Summary of Contents for Kroll TK30

  • Page 1 INSTRUCTION HANDBOOK Dehumidifier Original manual 057614-21 / March 2020...
  • Page 2: Table Of Contents

    TK30/TK60 CONTENTS PAGE 1 General notes 2 Construction and function of the dehumidifier 3 Safety 4 General safety instructions 5 Installation and transport 6 Electrical connection 7 Operation 7.1 Commissioning 7.2 Hygrostat control 7.3 Condensate drain 7.4 Automatic defrosting 8 Conditions of operation 9 Troubleshooting 10 Technical data 11 Maintenance 12 Wiring diagram...
  • Page 3: General Notes

    GENER AL NOTES You have purchased a KROLL dehumidifier, a product of high quality. If, however, there should be compli- cations, you will find in the following some instructions how to fix the problems as easily as possible. ATTENTION!  Check your dehumidifier for transport damages right at receipt! If you find any damages, please in- form the truck driver and note it on the delivery note before signing it!  If you find a damage after unpacking the unit, please contact immediately your responsible salesman...
  • Page 4: Safety

    TK30/TK60 3 SAFETY The dehumidifiers TK30/TK60 are equipped with safety devices. The units have been tested for safety. Wrong use or misuse may cause damage to: • the user, • the dehumidifier and other things in the same room, • the efficient operation of the dehumidifier.
  • Page 5: General Safety Instructions

    4 GENERAL SAFETY INSTRUCTIONS • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervi- sion or instruction concerning use of the appliance in a safe way and understand the hazards involved. • Children shall not play with the appliance. • Cleaning and user maintenance shall not be made by children without supervision. • Do not cover the unit during the operation. • The unit must be placed in a way that the air can circulate through it freely. The air filter and the lamellas of the front panel must be kept free. Keep a free space of 1 m from the lamellas and the front panel. • Before moving the unit, switch it off by pushing the ON/ OFF switch, take off the mains plug and empty the drip pan! • Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
  • Page 6: Installation And Transport

    TK30/TK60 5 INSTALLATION AND TR ANSPORT The dehumidifiers TK are designed for mobile use. For installation and transport, please consider the following points:  The unit must be placed in a way that the air can circulate through it freely. The air filter and the lamellas of the front panel must be kept free.
  • Page 7: Operation

    Before commissioning the unit, read the manual carefully in order to avoid damages caused by improper operation or local conditions. WARNING! Fire danger/material damage and unit damage! The unit TK30 contains the eco-friendly but flammable refrigerant R290. (TK60 / R454C) Keep naked flame and ignition sources away from the unit. In order to make the dehumidifier run, please stick to the following steps:  After any transport, the unit should stand still for about 15 minutes. During that time, the oil which has dis- tributed into the cooling system and become foamy due to the transport will flow back into the compressor.
  • Page 8: Hygrostat Control

    TK30/TK60 7.2 HYGROSTAT CONTROL The dehumidifier type TK is equipped with a hygrostat to set a desired value of air humidity. It is placed at the rear of the unit, on the control panel. You can set the value using the flat setting knob. The hygrostat makes the dehumidifier start when the air humidity in the room is higher than the set value.
  • Page 9: Automatic Defrosting

    They will operate without any problems in a temperature range from +5° C to +32° C at relative humidity of 50 % to 90 %. If you are not sure if the dehumidifier can work without problem on site due to local conditions, please contact KROLL or you dealer. If the dehumidifier is operated under non suitable conditions, the warranty expires! 9 TROUBLESHOOTING Problem Pos.
  • Page 10 TK30/TK60 The automatic circuit breaker The building’s fuse protection The building’s fuse fuse of the building’s protection is too weak. protection has to be checked fuse interrupts the mains and/or be changed. supply to the dehumidifier. There is an electrical pro- The power supply of the de- blem in the dehumidifier’s...
  • Page 11 There is some mistake in the Check if water drops into cooling circuit of the dehumi- the drip pan. If this is not difier. the case although the unit’s compressor has been wor- king all the time, contact your supplier. ATTENTION! Only trained professional staff is allowed to repair the unit! During the warranty period, only the supplier or people authorized by the supplier are allowed to carry out operations at the dehumidifier, otherwise the warranty expires! If you have questions regarding defects or problems in operating a KROLL dehu- midifier, we recommend to contact your dealer.
  • Page 12: Technical Data

    There are many components built in within a dehumidifier, all of them have an influence of the unit’s dehumidi- fying performance. As these components never can be identical, the actual dehumidifying performance may vary up to 5 % from the indicated values. 0 KROLL GmbH - Industrial Dehumidifiers TECHNICAL DATA FT.86-0...
  • Page 13: Maintenance

    11 MAINTENANCE ATTENTION! During maintenance works, the general safety guidelines must be observed! In order to ensure a trouble-free operation of the dehumidifier, it should be cleaned it regularly. We recommend to stick the following procedure:  Switch off the dehumidifier  Pull off the mains plug!  Take off the filter protection ...
  • Page 14: Wiring Diagram

    TK30/TK60 12 WIRING DIAGR AM...
  • Page 15 Functional principle with drip pan The dehumidifier works normally; the yellow lamp of the switch works l/0 (L1); When the amount of water is reached (about 6 l), the compensator is activated (about 6 kg); The dehumidifier turns off; The red lamp (L 2) near the switch l/0 (L1) starts to glow to show that the drip pan is full; As soon as the full drip pan is removed, the dehumidifier starts working again normally and the red lamp (L2) turns off.
  • Page 16 TK60 TK30/TK60...
  • Page 17 Einzelteile/Component parts/Nomenclature TK30 Abb. Deutsch Englisch Französisch Art.-Nr. Bodenplatte Base plate Plaque de fond 048463 Trennwand Partition wall Cloison de séparation 300419 Wassertankauflage Water tank bearing Support réservoir d’eau 300420 Ausblasgitter Outlet grille Grille de sortie 300421 Oberteil Housing Habillage 300422 Ansauggitter Intake grille Grille d‘aspiration...
  • Page 18 TK30/TK60 Einzelteile/Component parts/Nomenclature TK60 Abb. Deutsch Englisch Französisch Art.-Nr. Bodenplatte Base plate Plaque de fond 300431 Trennwand Partition wall Cloison de séparation 300432 Wassertankauflage Water tank bearing Support réservoir d’eau 300420 Ausblasgitter Outlet grille Grille de sortie 300433 Oberteil Housing Habillage 051236...
  • Page 20 версии, поставленной изготовителем, приводит к тому, что любые гарантии теряют силу. Кроме того, действуют наши „Условия продаж и поставки“. В изделие могут без уведомления вноситься технические модификации, направленные на усовершенствование изделия. Kroll Energy GmbH Pfarrgartenstraße 46 D-71737 Kirchberg/Murr Telefon: 0049 (0)7144 / 830 200...