SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRODUCTION AND A WALL MOUNTED BOILER
Electricity
RETE
ELETTRICA
Mains
VE
AF
V
S
Sc
TCN
ST
Ja
F
V
S
Kit N3 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product to
be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the
fireplace.
Components KIT N3
9
9
9
11
10
12
8
7
6
5
2
3
4
1
Electrical Connections
Sanitary-heating enabled setting
Enabled alarm
Electricity
Mains
T H E I N L E T A N D O U T L E T P I PE S M U ST B E C R O SS E D F O R T H I S TO F U N C TI O N PR O PE R LY
INT
KIT N3
TA
CA
circuit connected to
Circuito collegabile al
termostato ambiente
the room thermostat
(a discrezione del cliente)
RE
(implemented by the
client)
P1
must be connected to the
Da collegare necessariamente
V
heating system circulator
al circolatore dell'impianto
Vs
di riscaldamento
PR
PR
VR
V
V
VR
VR
ACS
ACS
13
4
1
3
2
Passacavi
Cable duct
18
16 17
15
Primary circulator enabled setting
Primary circuit pump
Heating pump
CA:
PR:
P1:
RE:
TA:
VE:
Ja:
V:
Water
VR:
AF
RETE
Mains
IDRICA
VR
V
ST:
VR
Collector
F:
COLLETTORE
Sc:
V
V
EV:
V
V
RI
MI
RI:
V
RA:
MI:
RA
AF:
ACS:
V
S:
1
2
3
4
5
6
7
8
9
10
7
6
11
14
12
13
14
15
5
16
17
18
Room thermostat
sensor
Flow sensor
KIT N3
KIT N3
USING
Wall Mounted Boiler
Pump (circulator)
Primary circuit pump
Electronic regulator
Room thermostat
Expansion Tank
Air refief Valve
Intercept valve
Retaining valve
Temperature Sensor
Flow switch
Heat plate exchanger
3-way solenoid valve
Heating system return
Radiators
Heating system flow
Cold water
Hot sanitary water
Drain
Heating system flow G 3/4"
EDILKAMIN generator flow G 3/4"
EDILKAMIN generator return G 3/4"
Heating system return G 3/4"
Cold sanitary water inlet G 1/2"
Hot water return to the sanitary system G 1/2"
Safety valve - temperature and pressure (90 °C - 3bar)
Flow Switch
Air relief valve G 3/8"
EDILKAMIN generator circuit circulator
3-way heat exchanger
Intercept valve G 1"
Electronic regulator with wiring
Appropriate aperture for the cable duct to pass through
Power cable
Cables for the heating system circulator
Temperature sensor
Room thermostat circuit
code 627690
(
phase, neutral, earth)