Important Safety Instructions; Hardware Setup; Rack Mounting; Single-Stage Installation - Tripp Lite NetDirector Cat5 Quick Start Manual

Ip kvm switches
Table of Contents

Advertisement

Important Safety Instructions

WARNING
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth
ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
AVERTISSEMENT
Équipement de classe I Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à
une prise de courant mise à la terre correctement câblée. Une prise de courant incorrectement câblée pourrait
introduire des tensions dangereuses sur des pièces de métal accessibles.
62368-1 Clause Equipment for Installation:
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645 du National Electrical Code et à la
NFPA 75.
BATTERY SAFETY NOTICE
There is a risk of explosion if the battery is replaced with an incorrect type. Dispose of used batteries according to
the relevant instructions.
BATTERIE AVIS DE SÉCURITÉ
II existe un risque d'explosion si la batterie est remplacée par un incorrect tapez. Jeter les piles usagées selon la
pertinente instructions.

1. Hardware Setup

1.1 Rack Mounting

The KVM switch can be mounted in a 19-in (1U) rack. The rack-mount brackets can be installed on either the front or the back of the unit so
that it can be mounted to the front or back of the rack.
1. Depending on whether you are mounting the unit from front or rear of the rack, remove the two screws located on both sides of the front
or back of the unit.
2. Use the screws supplied with the rack-mount kit to attach the rack-mount brackets to the front or rear of the unit.
3. Position the device in the front or rear of the rack and align the holes in the mount brackets with the holes in the rack.
4. Secure the rack-mount brackets to the rack using user-supplied screws.

1.2 Single-Stage Installation

In a single-stage installation, there are no additional KVM switches cascaded or daisy-chained from the B064-Series KVM. To set up a single-
stage installation, refer to the following instructions and the corresponding installation diagrams.
1. Make sure that power to all the devices you will be connecting, including all pre-existing devices on the installation, have been turned off.
2. Optional: Plug your Local Console's keyboard, monitor, and mouse into the KVM's Local Console Ports.
3. Use Cat5e cable to connect any available KVM port to a Server Interface Unit (SIU): B055-001-PS2 (PS/2), B055-001-SER (Serial),
B055-001-USB (USB) or B055-001-USB-V2 (USB with Virtual Media).
Use the M3x8 Phillips head hex screws
provided with the rack mount kit
2
Use user supplied
hardware to attach
to the rack