Information About Battery Passivation; To Determine Whether A Battery Requires Activation; How To Activate The Battery - netvox R718NL1 Series User Manual

Wireless light sensor and 1-phase current meter
Table of Contents

Advertisement

7. Information about Battery Passivation

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many
advantages including low self-discharge rate and high energy density.
However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium
anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
This lithium chloride layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride,
but battery passivation may also lead to voltage delay when the batteries are put into operation, and our devices may not work
correctly in this situation. As a result, please make sure to source batteries from reliable vendors, and the batteries should be
produced within the last three months.
If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis.

7.1 To determine whether a battery requires activation

Connect a new ER14505 battery to a 68ohm resistor in parallel, and check the voltage of the circuit.
If the voltage is below 3.3V, it means the battery requires activation.

7.2 How to activate the battery

a. Connect a battery to a 68ohm resistor in parallel
b. Keep the connection for 6~8 minutes
c. The voltage of the circuit should be ≧3.3V
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

R718nl1R718nl13R718nl17R718nl115R718nl125R718nl163

Table of Contents