netvox R718NL1 Series User Manual page 7

Wireless light sensor and 1-phase current meter
Table of Contents

Advertisement

Example of Report configuration
FPort:0x07
Bytes
1 Byte
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
ConfigReportReq
ConfigReportRsp
R718NL1
ReadConfig
ReportReq
ReadConfig
ReportRsp
(1) Configure report parameters MinTime = 1min, MaxTime = 1min, CurrentChange=100mA, IlluminanceChange= 100Lux
Downlink: 0198003C003C0064006400
The device returns:
8198000000000000000000 (Configuration succeeded)
8198010000000000000000 (Configuration failed)
(2) Read device configuration parameters
Downlink: 0298000000000000000000
The device returns:
8298003C003C0064006400 (current device configuration parameters)
Example for MinTime/MaxTime logic
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime
Sleeping(MinTime)
Wakes up and collects data
REPORTS 3.6V
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value.
1 Byte
DeviceType
Device
CmdID
Type
MinTime
0x01
(2bytes Unit:s)
0x81
0x98
0x02
MinTime
0x82
(2bytes Unit:s)
Wakes up and collects data
REPORTS 3.6V
Var(Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
CurrentChange
(2bytes Unit:s)
(2byte Unit:1mA)
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
MaxTime
CurrentChange
(2bytes Unit:s)
(2byte Unit:1mA)
MaxTime
Sleeping(MinTime)
Wake up and collects data
REPORTS 3.6V
6
Illuminancechange
Reserved
(2bytes Unit:1Lux)
(1Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Illuminancechange
Reserved
(2bytes Unit:1Lux)
(1Bytes,Fixed 0x00)