Toro Pro Control XP Operator's Manual page 8

Spray system multi-pro 5800 turf sprayer
Table of Contents

Advertisement

Keypad Reference Table
Key
BOOM 1 CAL
Length of boom 1
(1)
BOOM 2 CAL
Length of boom 2
(2)
BOOM 3 CAL
Length of boom 2
(3)
SPEED CAL
Speed calibration number
(4)
METER CAL
Flowmeter calibration number
(5)
VALVE CAL
Control valve response time
(6)
RATE 1 CAL
Target application rate 1
(7)
Target application rate 2
RATE 2 CAL
(8)
VOL / TANK
Volume of material remaining in the tank
(9)
TIME
24-hour clock
(0)
SELF TEST
Simulation of vehicle speed
(←)
CE
Clear Entry
TOTAL
Total area sprayed
AREA
TOTAL
Total volume of material sprayed
VOLUME
FIELD AREA Field area sprayed
FIELD
Volume of material sprayed onto a field or
VOLUME
specific area
DISTANCE
Distance of vehicle travel
SPEED
Vehicle speed
VOL / MIN
Volume of material sprayed per minute at
vehicle speed
AREA /
Area sprayed per hour at vehicle speed
HOUR
DATA MENU Area sprayed per hour at vehicle speed.
Preset agitation can be selected by
pressing the Data Menu until Preset
Agitation is displayed.
ENTER
Enter data
*The calibration numbers listed are for reference only. Before spraying, check your sprayer to ensure that the
numbers you are using are correct.
Description
It calculates the length of the boom by multiplying the number of
nozzles by the spacing between them in inches (cm) of the left boom.
80 inches (204 cm) is set as the default.
It calculates the length of the boom by multiplying the number of nozzles
by the spacing between them in inches (cm) of the center boom.
60 inches (152 cm) is set as the default.
It calculates the length of the boom by multiplying the number of
nozzles by the spacing between them in inches (cm) of the right boom.
80 inches (204 cm) is set as the default.
148 (US or TU) or 38 (SI) is set as the starting point for all Toro sprayers.
Enter the number found on the flowmeter label or the tag on the flowmeter
cable (Gal# for US or TU, or Liter# for SI).
It sets the system response.
Enter 23 is set as the starting point.
It is the first application rate.
It is the second application rate. If there is only one application rate,
use the Rate 1 value again.
It displays the volume of material in the sprayer tank. Reset the volume
when you refill the tank.
It is a 24 hour clock or an elapsed timer. You reset it when you turn off
the console computer.
It is used to simulate the vehicle speed to allow the operator to check and
calibrate the system operation while the vehicle is stationary.
It clears a wrong entry; enables you to toggle between settings during
initial programming; and enables you to select functions and settings.
It monitors the total area covered until you clear it to zero.
It monitors the volume of material sprayed until you clear it to zero.
It monitors the total area covered until you clear it to zero.
It monitors the volume of material applied until you clear it to zero.
It measures the distance the vehicle travels until you clear it to zero.
It displays the vehicle speed.
It displays the volume/minute that the system is currently using.
It displays acres, 1000 sq. ft., or hectares covered per hour at the vehicle
speed driven.
This allows you to adjust agitation pressure when the booms
are off. The setting is preset at 105.
Note: When the number increases, the agitation pressure increases. The
number is not the agitation pressure.