Hydraulic Manifold Block; Hydraulic Fitting - Toro Ultra Sonic Boom 41219 Installation Instructions Manual

Leveling kit for 2013 and after multi-pro 5800, 1750 and wm turf sprayers
Table of Contents

Advertisement

3. Install a flat washer on each of the 2 hex-head bolts
(3-1/4 inch).
4. Insert the bolts through the hinged welded tube
openings, hinges, and straps (Figure 3).
Figure 3
Hardware for a covered boom shown
1. Hex-head bolt
2. Flat washer
3. Welded tube opening
5. Install a flat washer on the exposed end of each of the
bolts.
6. Install a spring on the end of each bolt (Figure 3).
7. Install a flat washer and a locknut on the end of each
bolt, and tighten the locknuts until there is no slack
in the spring.
Note: Check to ensure that the hinges are not so tight
that the mounted sensors do not freely pivot on the
hinges.
4. Springs
5. Locknuts (5/16 inch)
3
Preparing the Booms
Parts needed for this procedure:
1

Hydraulic manifold block

4

Hydraulic fitting

Procedure
The booms are set at the factory to travel downward no
farther than the horizontal position. To enable the ultrasonic
boom kit to maintain a consistent distance between the
nozzles and the ground when the ground slopes downward
from the machine, you must adjust the boom support system
to allow the booms to travel below the horizontal position in
order to maintain a constant nozzle-to-ground distance.
1. Raise the booms and have them rest in the transport
cradle.
2. For each boom, remove the hairpin cotter and pull out
the pin from the rod to disconnect the rod from the
boom pivot pin housing (Figure 4).
Note: There should be no more than 16 mm (5/8
inch) of exposed thread on the eyelet to prevent the
engaged threads from stripping and the rod from
pulling away.